Manually Switching Relay
You can manually set the state of the relay
in
KIT-400R
via the OSD.
To define the relay functionality:
1. On the front panel press
MENU
. The menu appears.
2. Click
Advanced
.
3. Click
Relay
and define its state according to the information in the following table:
Menu Item
Function
ON
Turn the relay ON.
When on, the relay’s coil is energized, meaning C and NO are
shorted, and there is an open circuit between C and NC.
OFF
Turn the relay OFF
When off, the
relay’s coil is not energized, meaning C and NC are
shorted, and there is an open circuit between C and NO.
Relay is manually switched.
Defining CEC
KIT-400R
can be set to initiate and send CEC commands to the connected display, or to pass
CEC commands from its HDMI input to the connected display.
To set the CEC (Consumer Electronic Control) functionality:
1. On the front panel press
MENU
. The menu appears.
2. Click
Advanced
and select
Output CEC Bypass
.
3. Press
ENTER
and select:
▪
OFF
–
KIT-400R
automatically sends CEC commands to shut down the output
display after a timeout period when no input signal is found and to power up the
display when the input returns.
▪
ON
– CEC commands pass from the HDMI input to the display. (
KIT-400R
does not
automatically send CEC on and off commands).
KIT-400R
either passes CEC commands between its HDMI input and the display, or it
initiates and sends on and off commands to the display.
CEC is enabled/disabled.