Summary of Contents for MODULAR TBUS-1Axl

Page 1: ...PDF provided by Conference Room AV Kramer TBUS 1Axl B Table Well Modular AV Box with Tilt Up Lid Black...

Page 2: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 1Axl Table Connection Bus P N 2900 300055 Rev 3...

Page 3: ......

Page 4: ...bles 16 5 6 Inserting the Pass through Cables 17 5 7 Adjusting the Height of the Inner Frame 18 6 Using the TBUS 1Axl 19 7 Technical Specifications of the Assembled TBUS 1Axl 20 Figures UFigure 1 TBUS...

Page 5: ...at are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeat...

Page 6: ...1 Achieving the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise l...

Page 7: ...or the TBUS 1Axl according to your requirements A black anodized or brushed clear aluminum lid with a special opening for cable pass through note that other customized colors can also be ordered Heigh...

Page 8: ...tie through the holes to fix the pass through cables to the inside walls of the unit 6 Bracket Slits For attaching the two mounting brackets on opposite sides 7 Table Clamping Set Rubber Protectors Pr...

Page 9: ...ame T1AF 16 P N 80 000299 1 opening for 1 power socket 2 cable pass through inserts 4 blank inserts T1AF 26 P N 80 000399 1 opening for 2 power sockets 2 cable pass through inserts 4 blank inserts T1A...

Page 10: ...nserts You can install any wall plate devices as well as any of the single or dual inserts see our Web site for details T RC8IR P N 80 000599 1 special panel to fit the Kramer RC 8IR Control Panel int...

Page 11: ...if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country spec...

Page 12: ...wer outlet Germany and EU TS 2DE 80 002199 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet France TS 2FR 80 002299 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Italy TS 2IT 80 00239...

Page 13: ...ft 220V Israel C AC IL 220V 91 000999 6ft 250V UK C AC UK 250V 91 000299 6ft 250V India C AC IN 250V 91 001099 6ft 250V 10A China C AC CN 250V 91 001199 6ft 250V 10A South Africa C AC ZA 250V 91 00129...

Page 14: ...mounted on the inner frame can include single inserts and or dual inserts as well as power sockets and various Kramer devices This section describes how to assemble these modules i Each module kit com...

Page 15: ...gle power socket or the T 2INSERT 5 Adjustable Height Screw Holes For adjusting the height of the inner frame 5 1 2 Mounting the Power Socket Assemblies To mount the power socket place the power socke...

Page 16: ...me holes and spacers Figure 4 Installing a Kramer TOOL 5 1 4 Installing the TOOL Blank To install the T TBLANK as shown in Figure 5 1 Insert the T TBLANK from beneath through the TOOL opening 2 Screw...

Page 17: ...80 000499 instead of two power sockets Faceplate Attachment hole Faceplate Attachment hole Inner Frame Attachment hole Inner Frame Attachment hole IR IN Opening Figure 6 T RC8IR P N 80 000599 Remove...

Page 18: ...2 Use the two power socket screws to tighten the T RC8IR assembly in place 5 1 6 Installing the SI 1VGA RC 3TB To install the SI 1VGA RC 3TB module place it under the designated opening in the T1AF 1...

Page 19: ...out template 3 Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure not to scale 8 i The thickness of the t...

Page 20: ...cket grooves on both sides of the unit see Figure 2 item 7 4 Verify proper alignment of the unit before tightening the mounting screws 5 Tighten both mounting butterfly screws upward until they reach...

Page 21: ...through bracket 2 Remove the split grommet 3 Insert the cable through the rectangular opening 4 Open the split grommet slightly and insert the required cables 5 Place the split bracket around the grom...

Page 22: ...adjust the inner frame height to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers...

Page 23: ...sing the TBUS 1Axl Once the TBUS 1Axl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 11 Figure...

Page 24: ...srael 220V AC 50 60Hz 5A Maximum 5A per power outlet South Africa 220V AC 50 60Hz 5A Maximum 5A per power outlet Dual Power Kit Assemblies Universal 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power ou...

Page 25: ...TBUS 1Axl 21...