background image

Kramer Electronics Ltd. 

 

RTBUS-27xl 

– Introduction 

 

Recycling Kramer Products 

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce 
the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected 
and recycled. To comply with the WEEE Directive, Kramer Electronics has made 
arrangements with the European Advanced Recycling Network (EARN) and will cover any 
costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on 
arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular 
country go to our recycling pages at 

www.kramerav.com/support/recycling

. 

Overview 

Congratulations on purchasing your Kramer 

RTBUS-27xl

 

Round Table

 

Connection Bus

.  

The 

RTBUS-27xl

 

is an elegant furniture-mounted, round connection bus. The 

RTBUS-27xl

 

features a mechanism for pneumatic lifting and smooth closing of its lid. It is easily installed 
into a table or podium top, and its

 

interface

 

enables you to connect any equipment to systems 

installed in a room: 

  C14 power socket opening, suitable for any of the following power sockets: for the USA, 

the UK, Germany (the Europlug), Belgium-France, Switzerland, Italy, Australia, Brazil, 
Israel, South Africa or “Universal” for use anywhere (see 

Power Socket Options

 

on page 

5

)

 

Power sockets are ordered separately. 

  Two pass-through openings for cables, located on the lower surface, enabling closing of 

the lid while keeping the cables hidden and protected under the surface. 

 

  

Summary of Contents for RTBUS-27xl

Page 1: ...P N 2900 301349 Rev 1 www kramerAV com USER MANUAL MODEL RTBUS 27xl Round Table Connection Bus ...

Page 2: ...ng RTBUS 27xl Round Table Connection Bus 3 The RTBUS 27xl Connecting Surface 4 Power Socket Options 5 Installing the RTBUS 27xl 6 Drilling a Hole in the Table 6 Installing the Power Socket 6 Connecting the Cables 7 Mounting the RTBUS 27xl in the Table 9 Using the RTBUS 27xl 10 Technical Specifications 11 ...

Page 3: ...terference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer RTBUS 27xl away from moisture excessive sunlight and dust Safety Inst...

Page 4: ...rav com support recycling Overview Congratulations on purchasing your Kramer RTBUS 27xl Round Table Connection Bus The RTBUS 27xl is an elegant furniture mounted round connection bus The RTBUS 27xl features a mechanism for pneumatic lifting and smooth closing of its lid It is easily installed into a table or podium top and its interface enables you to connect any equipment to systems installed in ...

Page 5: ...US 27xl to the table Locking Butterfly Nuts x2 Tighten to lock the mounting butterfly screw Mounting Butterfly Nuts x2 Tighten to secure the unit to the table surface Mounting Brackets x2 Place in the bracket slits after inserting the enclosure into the table for securing the unit to the table surface Black anodized or brushed aluminum semi automatic lid Covers the connecting surface leaving the t...

Page 6: ...gure 2 RTBUS 27xl Connecting Surface Feature Function Detachable Pass through Bracket Remove and re install to insert cables Pass Through Opening and Bushing x2 Insert a cable through the opening and the bushing 5A MAX Power Socket Connects to 90 240V AC power consuming device see Power Socket Options on page 5 Lid Latch For safely closing the lid 14 13 12 11 ...

Page 7: ...ket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not compatible with South African plugs Power Socket Type Power Specs Power Socket Type Power Specs USA TS 201US 80 000046 100 125V AC 50 60Hz 5A Maximum 5A per power outlet Italy TS 201IT 80 000047 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Germany and EU TS 201DE 8...

Page 8: ...n the table surface Take care not to damage the table Kramer AV is not responsible for any damage caused to the table Installing the Power Socket Figure 3 shows an example of the Universal power socket housing which is one of the optional power sockets for the RTBUS 27xl see Power Socket Options on page 5 To install the power socket purchased separately 1 Close the RTBUS 27xl lid 2 Carefully inser...

Page 9: ...TBUS 27xl on a table or after it is mounted usually if the RTBUS 27xl is mounted and you need to replace the cables To connect the cables 1 Unscrew the two detachable bracket screws to remove it from the lower surface Keep the bushing s and screws on the side for later 2 Insert a cable into an opening and place the bushing around the cable ...

Page 10: ...S 27xl Installing the RTBUS 27xl 8 3 Replace the detachable bracket and fix using the two screws and push the bushing into the pass through opening We recommend that you use the Kramer C AC AC Power Cord series to power the unit ...

Page 11: ...l into the hole cut into the table making sure the outer rim is firm against the surface of the table 2 From underneath the table slide the mounting brackets into the appropriate slots 3 Step 3 Tighten the butterfly mounting screws securely upward against the table 4 Lock the mounting screws into position with the locking butterfly screws ...

Page 12: ...BUS 27xl 10 Using the RTBUS 27xl Once the RTBUS 27xl is installed you can easily customize it to your own needs by directly plugging in the required AV equipment as illustrated in the example in Figure 4 5 Figure 4 RTBUS 25xl Boardroom Installation ...

Page 13: ...tlet Italy 100 240V AC 50 60Hz 5A maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A maximum 5A per power outlet Israel 220V AC 50 60Hz 5A maximum 5A per power outlet South Africa 220V AC 50 60Hz 5A maximum 5A per power outlet Switzerland 220V AC 50 60Hz 5A maximum 5A per power outlet England 220V AC 50 60Hz 5A maximum 5A per power outlet Brazil 220V AC 50 60Hz 5A maximum 5A per power ou...

Page 14: ...d or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any insta...

Page 15: ...and a list of Kramer distributors visit our website where updates to this user manual may be found We welcome your questions comments and feedback The terms HDMI HDMI High Definition Multimedia Interface and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator Inc All brand names product names and trademarks are the property of their respective owners ...

Reviews: