Using the SG-6006
KRAMER: SIMPLE CREATIVE TECHNOLOGY
10
#
Menu Item
Submenu
Default Value
CLICK IN LEFT CHANNELS
1
DISABLE, 1 SEC to 4
SEC
DISABLE
7
SET …GENLOCK (enter submenu)
FACTORY RESET
Press ENTER to reset the
GENLOCK parameters
GENLOCK MODE
HV only, HV and SC
HV only
GENLOCK TIMING HORIZONTAL
from -31968ns to
+31968ns (in 37ns steps)
2
0
GENLOCK TIMING VERTICAL
from -625 line to +625 line 0
GENLOCK EXTRA V SHIFT
-1 frame, 0 frame, +1
frame
0 frame
GENLOCK SC PHASE SHIFT
from -185
°
to +185
°
0
NON-GENLOCK or HVmode
SCHphase
from -64
°
to +63
°
0
8
TEST 1 PROGRAMMING
TEST 2 PROGRAMMING
9
ADDRESS OF machine
First, Second
First
7.2 Locking the Front Panel
To prevent changing the settings accidentally or tampering with the unit via the
front panel buttons, lock your
SG-6006
. Unlocking releases the protection
mechanism.
To lock the SG-6006:
•
Press the LOCK button for more than three seconds, until the LOCK button
lights
•
The front panel is locked. Pressing a button will have no effect other than
causing the LOCK button to flash
2
To unlock the SG-6006:
•
Press the lit LOCK button for more than three seconds, until the LOCK button
no longer lights
The front panel unlocks
7.3
Remotely Operating the SG-6006 via RS-232
You can remotely operate the
SG-6006
via RS-232 using a device such as a PC.
To connect a PC to the SG-6006 unit using the Null-modem adapter provided
with the machine (recommended):
•
Connect the RS-232 9-pin D-sub rear panel port on the
SG-6006
unit to the
Null-modem adapter and connect the Null-modem adapter with a 9-wire flat
cable to the RS-232 9-pin D-sub port on your PC
To connect a PC to the SG-6006 unit, without using a Null-modem adapter:
•
Connect the RS-232 9-pin D-sub port on your PC to the RS-232 9-pin D-sub
1 Insert a pulse signal and select the pulse rate
2 Warning that you need to unlock to regain control via the front panel