10
TP-121xl/TP-122xl - Operating the TP-121xl and TP-122xl
6
Operating the TP-121xl and TP-122xl
6.1
Capturing the EDID
The
TP-121xl
is programmed with a default EDID. The default EDID can be
replaced with the EDID from a display device.
To capture a new EDID
:
With the display device connected to the
TP-121xl
, press the EDID Capture
button on the front panel.
If the EDID is successfully captured the Status LED flashes slowly for a few
seconds and then lights solid. If the EDID is not successfully captured the
Status LED flashes quickly for a few seconds then lights solid when the
default EDID is loaded.
6.2
Adjusting the Level and Equalization on the TP-122xl
To achieve optimum picture quality, you can manually adjust the signal level and
equalization using the trimmers on the front of the
TP-122xl
.
To adjust the level and equalization on the TP-122xl
:
1. Use a small screwdriver to slowly turn the Level trimmer clockwise to
increase or anticlockwise to reduce the signal level of the
TP-122xl
.
2. Use a small screwdriver to slowly turn the EQ trimmer clockwise or
anticlockwise until you achieve an optimum picture.