background image

Kramer Electronics Ltd. 

 

TP-594Txr, TP-594Rxr 

– Routing Audio Signals 

18 

 

The 

TP-594Txr

 received ARC signal is routed to the HDMI IN and analog audio outputs 

according to the 

Audio Line-ARC Extraction Destination

 (see 

Setting Audio Parameters

 

on page 

34

)

 

Figure 19: Setting Audio Line-ARC Extraction Destination on TP-594Txr 

 

When ARC De-embedding Destination is set to 

Analog-out

, the analog AUDIO port 

should not be connected to an analog audio source. 

 

  

DRAFT

Summary of Contents for TP-594Rxr

Page 1: ...P N 2900 301015 Rev 1 www kramerAV com USER MANUAL MODELS TP 594Txr HDMI Line Transmitter TP 594Rxr HDMI Line Receiver D R A F T ...

Page 2: ...nding HDMI CEC Commands via HDMI Connections 20 Routing IP Driven Control Signals via Built in Control Gateway 20 Operating and Controlling TP 594Txr and TP 594Rxr 22 Setting the DIP Switches 22 Operating via Ethernet 23 Using the Embedded Web Pages 25 Browsing the Web Pages 25 Viewing General Information 28 Viewing Connected Clients 28 Changing Device Settings 29 Defining TP 594Txr Video and Audi...

Page 3: ...bles we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your ...

Page 4: ... up to 4K 60Hz 4 4 4 24bpp video resolution and provide even further reach for lower HD video resolutions TP 594Txr and TP 594Rxr are standard extenders that can operate together as a transmitter receiver system but can also be matched with any market available HDBaseT compliant Tx or Rx extender auto detecting and adapting to the peer device capabilities TP 594Txr and TP 594Rxr provide exceptiona...

Page 5: ...s selected by the user the ARC signal received from the HDMI output the digital audio input or the analog audio bidirectional port is routed back to the transmitter via the HDBaseT link This enables high quality ARC playback and user volume control by routing the ARC to audio speakers connected on the transmitter side either directly or via an AV acceptor device such as an AV Receiver with speaker...

Page 6: ...s allowing remote control of peripheral devices located at either end of the extended link Typical Applications TP 594Txr TP 594Rxr is ideal for the following typical applications Single cable 4K HDR AV and ARC extension for AV receiver connectivity in large residential rooms Smooth integration with standard 4K AV and control systems providing intelligent ARC and audio routing Long distance 4K HDR...

Page 7: ...her a stereo balanced audio source or acceptor the connection type is defined via the embedded web pages Connect an audio source to extend an audio signal from TP 594Txr to the audio acceptor on the receiver side via the HDBT link Connect an audio acceptor to output the audio signal received from the audio source on TP 594Rxr via the HDBT link TOSLINK OUT Connector Digital audio on a TOSLINK optic...

Page 8: ...that is controlled via the Ethernet see Defining TP 594Rxr Gateway and Ports Activation on page 38 AUDIO 5 pin Terminal Block Connector Connect to a stereo balanced audio source or an acceptor the connection type is defined via the embedded web pages Connect an audio acceptor to output the audio signal received from the audio source on the transmitter side via the HDBT link Connect an audio source...

Page 9: ...rature air flow is compatible for the device Avoid uneven mechanical loading Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits Reliable earthing of rack mounted equipment should be maintained Maximum mounting height for the device is 2 meters To mount the TP 594Txr TP 594Rxr in a rack Mount the unit in a rack using the recommended rack...

Page 10: ...Figure 3 Connecting to the TP 594Txr Rear Panel To connect the TP 594Txr and TP 594Rxr as illustrated in the example in Figure 3 Connect the inputs and outputs 1 On TP 594Txr Connect the HDMI source for example an AV receiver to the HDMI IN connector Connect an audio source for example a microphone via the Kramer 102MX 2 channel audio mixer to the AUDIO 5 pin terminal block connector 2 On TP 594Rx...

Page 11: ... room controller to the ETHERNET RJ 45 port On TP 594Rxr connect the ETHERNET RJ 45 port to a relay control gateway for example the Kramer FC 7 On FC 7 connect the relay to the blinds in the room Send open close commands from SL 240C to FC 7 to the blinds via the Ethernet 7 Output the smart TV audio via TOSLINK connections to the AV receiver On TP 594Rxr connect the smart TV acceptor to the TOSLIN...

Page 12: ...section TP 594Txr is taken as an example TP 594Txr and TP 594Rxr connect to RS 232 ports in the same way You can connect to the TP 594Txr via an RS 232 connection using for example a PC The TP 594Txr features an RS 232 3 pin terminal block connector allowing the RS 232 to control the TP 594Txr or for signal extension over HDBT Connect the RS 232 terminal block on the rear panel of the TP 594Txr to...

Page 13: ...ines the HDBaseT pinout using a straight pin to pin cable with RJ 45 connectors For HDBT cables it is recommended that the cable ground shielding be connected soldered to the connector shield EIA TIA 568B PIN Wire Color 1 Orange White 2 Orange 3 Green White 4 Blue 5 Blue White 6 Green 7 Brown White 8 Brown D R A F T ...

Page 14: ...e to the Receiver for Auto play when No Video Signal is Present on page 15 Routing an Analog Audio Source to the Receiver To route the analog audio source to the receiver 1 Connect an audio source to the AUDIO 5 pin terminal block connector 2 If required connect an HDMI source to the HDMI connector 3 In the TP 594Txr Navigation pane click Video Audio The Video and Audio settings page appears 4 Und...

Page 15: ...o the TP 594Rxr HDMI and analog audio outputs Routing HDMI Audio Source to the Receiver To route the HDMI audio source to the receiver 1 Connect an HDMI source to the HDMI connector 2 If required connect an analog audio source to the AUDIO 5 pin terminal block connector 3 In the TP 594Txr Navigation pane click Video Audio The Video and Audio settings page appears 4 Under Audio Settings Set Audio E...

Page 16: ...e automatically 1 Connect an analog audio source to the AUDIO 5 pin terminal block connector and or the HDMI connector 2 In the TP 594Txr Navigation pane click Video Audio The Video and Audio settings page appears 3 Under Audio Settings Set Audio Embedding Selection Mode to Auto Set Audio Embedding Selection Priority to Analog HDMI In this example the audio embedding source priority is set to anal...

Page 17: ...route the analog audio source to the receiver without video signal display 1 Connect an audio source to the AUDIO 5 pin terminal block connector 2 Mute or disconnect the HDMI source connected to the HDMI connector 3 In the TP 594Txr Navigation pane click Video Audio The Video and Audio settings page appears 4 Under Video Settings Set Analog Audio Auto play Upon No Video Signal to On Figure 14 TP 5...

Page 18: ...io output and played on its connected speakers with a black screen on the display Routing TP 594Rxr Audio Signals TP 594Rxr provides several audio sources that are defined via the web pages the HDMI OUT ARC the TOSLINK IN digital input or Analog AUDIO defined as an input After defining the ARC source see Defining the ARC Source on page 16 perform the following operations Routing HDMI out ARC signa...

Page 19: ... to HDMI out ARC Set Audio De embedding Destination to Analog OUT Figure 17 TP 594Rxr Video and Audio Page Routing ARC to TP 594Rxr Analog Audio HDMI OUT ARC is routed to the AUDIO analog port on the TP 594Rxr and to the TP 594Txr via the HDBT link Routing Audio Return Signals on TP 594Txr The following audio ports accept ARC on the transmitter HDMI IN AUDIO TOSLINK OUT The ARC signals are defined...

Page 20: ...N and analog audio outputs according to the Audio Line ARC Extraction Destination see Setting Audio Parameters on page 34 Figure 19 Setting Audio Line ARC Extraction Destination on TP 594Txr When ARC De embedding Destination is set to Analog out the analog AUDIO port should not be connected to an analog audio source D R A F T ...

Page 21: ...devices The example in Figure 20 shows RS 232 signal extension Serial control signals are extended via HDBT between the SL 240C that is connected to the RS 232 port on the transmitter side and the RS 232 port on the receiver side that is connected to the smart TV IR signal extension The smart TV IR remote control unit sends an IR command signal via an IR sensor cable that is connected to the trans...

Page 22: ...gure 21 CEC End to End Extension Routing IP Driven Control Signals via Built in Control Gateway Remote IP connected clients can send from the LAN via the TP 594Rxr built in control gateway CEC RS 232 and IR commands to control devices connected to TP 594Rxr HDMI CEC RS 232 and IR control ports The built in control gateway sends the control commands converted from the client received IP messages to...

Page 23: ...eway enable disable activation enable disable activation of the associated control ports and the control gateway CEC configuration such as the CEC logical address of the control gateway as well as its manual commands sending operation is done via TP 594Rxr control gateway webpages see Defining TP 594Rxr Gateway and Ports Activation on page 38 D R A F T ...

Page 24: ... is activated when DIP switch 1 on at least one of the devices is set to ON 2 IR Pass through OFF up Pass through the IR signal to the IR port via IR cable ON down Add IR modulation to the IR output signal applies only when the IR port is connected to an IR emitter cable The IR Pass through DIP switch setup depends on the IR control configuration We recommend that you test which position best suit...

Page 25: ...tions Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the TP 594Txr directly to the Ethernet port on your PC using a crossover cable with RJ 45 connectors This type of connection is recommended for identifying the TP 594Txr with the factory configured default IP address After connecting the TP 594Txr to the Ethernet port configure your PC as follows 1 Click Start...

Page 26: ...Obtain an IP address automatically for dynamic IP addressing allocation and use any IP address that is provided by your IT department DHCP server 7 Click OK 8 Click Close Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the TP 594Txr to the Ethernet port on a network hub or using a straight through cable with RJ 45 connectors Configuring the Ethernet Po...

Page 27: ...ore attempting to connect Perform the procedures in Configuring the Ethernet Port on page 24 Ensure that your browser is supported The following operating systems and Web browsers are supported Operating Systems Versions Windows 7 IE Firefox Chrome Safari Windows 10 IE Edge Firefox Chrome Mac Safari iOS Safari Note that some features might not be supported by some cellphone operating systems Brows...

Page 28: ...ntering the device name or IP Address 2 If the page is secured once you enter the device name IP Address the Authentication window appears Figure 28 Using the Embedded Web Pages Authentication Window 3 Enter the Username and Password Admin Admin by default and click the arrow button The General Info page appears For TP 594Txr Figure 29 TP 594Txr Routing Settings Page with Navigation List on Left D...

Page 29: ...side of the main page The lower part of the screen lets you save the settings and upload a saved setting The TP 594Txr and TP 594Rxr web pages enable performing the following functions Viewing General Information on page 28 Viewing Connected Clients on page 28 Changing Device Settings on page 29 Defining TP 594Txr Video and Audio Settings on page 33 Defining TP 594Rxr Video and Audio Settings on p...

Page 30: ...l Info Page Viewing Connected Clients Up to 4 connected TCP clients and 4 connected UDP clients can be IP connected to TP 594Txr TP 594Rxr control gateway for simultaneous control of the device itself as well as peripheral devices such as projectors displays and DVD players To view the connected clients list in the Navigation pane click Connected Clients page The Connected Clients page opens Figur...

Page 31: ...t number via the Device Settings page Changing the IP Settings on page 30 and set the control gateway port numbers for TP 594Rxr via see Setting TP 594Rxr Gateway Serial Port Settings on page 41 Changing Device Settings Use the Device Settings page to change the TP 594Txr TP 594Rxr name click SET and perform the following operations Changing the IP Settings on page 30 Viewing the HDBT range mode s...

Page 32: ...t or OFF When DHCP is checked IP Address shows the device acquired IP address from the DHCP server Static IP Address gateway and Subnet are disabled Static IP Address is the actual IP address when operating in the non DHCP mode and is also the fallback IP address auto acquired after no DHCP server detection with default set to 192 168 1 39 for TP 594Txr 192 168 1 40 for TP 594Rxr The confirmation ...

Page 33: ...d in the example in Figure 35 Figure 35 The Device Settings Page Static IP Setting Confirmation 6 Click OK Ethernet parameters are changed Viewing HDBT Settings View HDBT Extra Range settings as set by the DIP switches see Setting the DIP Switches on page 22 Upgrading the Firmware To upgrade the firmware 1 In the Navigation pane click Device Settings The Device Settings page appears 2 Click Choose...

Page 34: ...wer left side Figure 37 The Device Settings Page New Firmware Updated Soft Factory Reset To reset the device to its factory default parameters except for IP parameters 1 In the Navigation pane click Device Settings The Device Settings page appears 2 Click Soft Factory reset the following message appears Figure 38 Device Settings Page Soft Factory Reset Message 3 Click OK and wait for the web page ...

Page 35: ...Video and Audio settings page appears Figure 39 TP 594Txr Video Audio Page 2 View the HDCP Input status Once an input is connected TP 594Txr automatically detects input signal HDCP status 3 Set the following Enable default or Disable HDCP Mode for HDCP support on the HDMI input Enable default or Disable DSC Compression Display Stream Compression DSC enables standard visually lossless compression f...

Page 36: ...Signal detected Upon New Signal Delay Switching When a new HDMI signal is detected while the analog audio input is active delay the switching from analog audio input to the HDMI embedded audio 0 to 90 0 None Signal loss Upon Signal Loss delay switching Leave 5V ON When the signal is lost either because the source is on standby or in the sleep mode delay the switching to analog audio input 5 to 90 ...

Page 37: ...and Analog is set as the priority Timeout Description Range sec Default sec Limitation Signal detected Upon New Signal Delay Switching When a new analog audio signal is detected delay the switching from HDMI to the analog audio input embedding 0 to 90 0 None Signal loss Upon signal loss Delay Switching Leave 5V ON When the analog audio signal is lost delay the switching to HDMI audio 60 to 180 60 ...

Page 38: ...l on HDMI OUT as the ARC source Analog IN Select the input signal on the TP 594Rxr AUDIO 5 pin terminal block connector as the ARC source Digital IN Select the TOSLINK IN input signal as the ARC source None Do not select ARC 3 Select the audio de embedding source for analog audio output Line HDMI IN From the HDMI IN on the transmitter via HDBT Line HDMI out ARC From the HDMI OUT audio return signa...

Page 39: ...ng the Embedded Web Pages 37 To acquire the EDID from the default EDID 1 In the Navigation pane click EDID The EDID management page appears 2 Click Default Figure 41 TP 594Txr EDID Management Page Figure 42 TP 594Rxr EDID Management Page D R A F T ...

Page 40: ...t To load a custom EDID file 1 In the Navigation pane click EDID The EDID management page appears 2 In the File area click Choose a file to browse for the custom EDID file location 3 Open the custom EDID file 4 Click Copy and follow the instructions on screen Defining TP 594Rxr Gateway and Ports Activation Use the TP 594Rxr Control Gateway page to either extend HDMI CEC RS 232 and IR commands bidi...

Page 41: ...ay connected IP clients can send IP messages see Protocol 3000 on page 51 to control devices connected to gateway enabled control ports see below IR RS 232 CEC and receive their control responses over the IP connection Disable control gateway default devices connected to the RS232 IR control ports are controlled via extended control signals from the transmitter over the HDBT link while CEC control...

Page 42: ...ntroI gateway attributes Enter the CEC logical address 14 by default of the control gateway View the list of logical addresses for CEC enabled devices connected on HDMI line as members of the CEC control channel Click CEC List Refresh to update the logical address list of CEC members According to HDMI CEC standard for proper identification during CEC control communication each CEC enabled member o...

Page 43: ...eway Serial Port Settings page to enable access from connected IP clients to the control gateway for sending IP messages see Protocol 3000 on page 51 to serially control the device that is connected to the TP 594Rxr RS 232 port and receive its control responses over the IP connection To set the gateway serial port settings 1 In the Navigation pane select Control Gateway Serial The Gateway Serial P...

Page 44: ...r the TCP and UDP port numbers to connect to clients 6 Define whether a new client automatically receives control responses from RS 232 On or can only send control commands Off Setting Web Page Access Permission To define access permission to the web pages in the Navigation pane click Security The Security page appears By default the web pages are secured username and password are both Admin To ch...

Page 45: ...ppears Figure 49 Security Password Change Confirmation 5 Click OK Username and password have changed To disable security 1 In the Navigation pane click Security The Security page appears 2 Uncheck Authenticate Web pages Access Current credentials are grayed out 3 Click Set changes The following message appears Figure 50 Security Security Disable Confirmation 4 Click OK Authentication is not requir...

Page 46: ...enticate Web pages Access Previous credentials are restored 3 Click Set changes The following message appears Figure 51 Security Security Enable Confirmation 4 Click OK appears and authentication is now required Viewing the About Page In the Navigation pane click About to view the TP 594Txr Web page version and Kramer Electronics Ltd details Figure 52 About Page D R A F T ...

Page 47: ...rom our website at www kramerav com support product_downloads asp Directly using a memory stick see Upgrading the Firmware Using a Memory Stick on page 45 Upgrading the Firmware Using a Memory Stick You can upgrade TP 594Txr TP 594Rxr via the USB port on the rear panel To upgrade the firmware via the USB port 1 Download the firmware Bin file and copy it to the root folder of a USB flash drive memo...

Page 48: ...mum extension ranges Compression Low level standard DSC compression for signals above 4K 60 4 2 0 4K 60 4 4 4 Range Compression up to 100m 330ft 4K 60 4 2 0 Range No compression up to 100m 330ft Full HD 1080p 60Hz Range No compression up to 130m 430ft Ultra long mode up to 180m 590ft Compliance HDBaseT 2 0 Video Max Bandwidth Compression 17 95Gbps 5 98Gbps per graphic channel No compression 10 2Gb...

Page 49: ... ventilation General Net Dimensions W D H each 18 7cm x 11 5cm x 2 5cm 7 4 x 4 5 x 1 Shipping Dimensions W D H 34 5cm x 16 5cm x 5 2 cm 13 6 x 6 5 x 2 Net Weight each 0 4kg 0 9bs approx Shipping Weight 0 95kg 2 1lbs approx Accessories Included 1 power adapter 1 power cord and 1 bracket set per device Specifications are subject to change without notice at www kramerav com D R A F T ...

Page 50: ...Y command and use RESET to restore the factory default values Default EDID Monitor Model name VM 10H2 Manufacturer KMR Plug and Play ID KMR1200 Serial number n a Manufacture date 2016 ISO week 14 Filter driver None EDID revision 1 3 Input signal type Digital Color bit depth Undefined Display type Monochrome grayscale Screen size 520 x 320 mm 24 0 in Power management Standby Suspend Active off slee...

Page 51: ...366x768p at 50Hz 16 9 Modeline 1366x768 84 650 1366 1894 1943 2086 768 772 777 813 hsync vsync Detailed timing 4 1366x768p at 60Hz 16 9 Modeline 1366x768 101 610 1366 1894 1943 2086 768 772 777 813 hsync vsync Detailed timing 5 720x576p at 50Hz 4 3 Modeline 720x576 27 370 720 728 841 880 576 578 596 621 hsync vsync CE video identifiers VICs timing formats supported 1920 x 1080p at 60Hz HDTV 16 9 1...

Page 52: ...2 3A 80 18 71 38 2D 40 58 2C 45 00 0 F 24 21 00 00 1E 00 00 00 FD 00 38 4C 1E 53 11 00 0A 20 20 20 20 20 20 00 00 00 FC 00 56 4 D 2D 31 30 48 32 0A 20 20 20 20 20 00 00 00 F7 00 00 08 42 A2 20 00 00 00 00 00 00 00 00 01 AF 3 02 03 2 C1 50 90 05 02 14 1F 20 22 5D 5F 61 62 64 66 67 69 6B 23 09 07 07 83 01 00 00 65 03 0C 00 10 03 51 03 D0 05 21 F0 2D 00 58 31 45 00 0F 1A 21 00 00 9E 51 13 54 D0 32 E0...

Page 53: ...ix nn Command Parameter CR LF Command parameters Multiple parameters must be separated by a comma In addition multiple parameters can be grouped as a single parameter using brackets and Command chain separator character Multiple commands can be chained in the same string Each command is delimited by a pipe character Parameters attributes Parameters may contain multiple attributes Attributes are in...

Page 54: ...GNAL inp_id CR FEEDBACK nn AUD SIGNAL inp_id status CR LF inp_id Input number 1 Input 1 status On Off 0 Off no signal 1 On signal present Get the status of input 1 AUD SIGNAL 1 CR AV SW TIMEOUT TP 594Txr TP 594Rxr Set auto switching timeout COMMAND AV SW TIMEOUT action time_out CR FEEDBACK nn AV SW TIMEOUT action time_out CR LF action 4 Disable 5V on video output if no input signal detected time_o...

Page 55: ...Add a communication route tunnel connection COM ROUTE ADD 1 1 1 1 1 CR COM ROUTE REMOVE TP 594Rxr Remove a communication route tunnel connection COMMAND COM ROUTE REMOVE ComNum CR FEEDBACK nn COM ROUTE REMOVE ComNum CR LF Com_Num 1 Remove a communication route tunnel connection COM ROUTE REMOVE 1 CR CPEDID TP 594Txr TP 594Rxr Copy EDID data from the output to the input EEPROM Destination bitmap si...

Page 56: ...COMMAND FACTORY CR FEEDBACK nn FACTORY OK CR LF Reset the device to factory default configuration FACTORY CR GLOBAL GW ACTIVE TP 594Rxr Set global activation state of the gateway device COMMAND GLOBAL GW ACTIVE state CR FEEDBACK nn GLOBAL GW ACTIVE state CR LF state Global gateway activation state OFF gateway is deactivated ON gateway is acivated Set the global state of the gateway to active GLOBA...

Page 57: ... unit Get inputs count INFO IO CR IR SND TP 594Rxr Send IR command to port COMMAND IR SND PortNum Cmdid CmdName Repeat TotalPackages Package Num pronto command CR FEEDBACK nn IR SND PortNum Cmdid CmdName Status CR LF Port_Num IR port transmitting the command broadcasts to all ports 1 port number Cmd_id Serial number of command for flow control and response commands from device 0 to 255 CmdName Com...

Page 58: ...hen set login must be performed upon each connection The permission system works only if security is enabled with the SECUR command It is not mandatory to enable the permission system in order to use the device In each device some connections allow logging in to different levels Some do not work with security at all Connection may logout after timeout COMMAND LOGIN login_level password logout_time...

Page 59: ...alpha numeric chars can include hyphen not at the beginning or end Set the DNS name of the device to room 442 NAME room 442 CR NAME TP 594Txr TP 594Rxr Get machine DNS name The machine name is not the same as the model name The machine name is used to identify a specific machine or a network in use with DNS feature on COMMAND NAME CR FEEDBACK nn NAME machine_name CR LF machine_name String of up to...

Page 60: ... is 0 additional ports are 1 2 3 mac_address Unique MAC address Format XX XX XX XX XX XX where X is hex digit NET MAC id CR NET MASK TP 594Txr TP 594Rxr Set subnet mask For proper settings consult your network administrator COMMAND NET MASK net_mask CR FEEDBACK nn NET MASK net_mask CR LF net_mask Format xxx xxx xxx xxx Set the subnet mask to 255 255 0 0 NET MASK 255 255 000 000 CR NET MASK TP 594T...

Page 61: ...device firmware version number VERSION CR VID COMPRESSION TP 594Txr Set compression attributes COMMAND VID COMPRESSION stage stage_id algorithm level CR FEEDBACK nn VID COMPRESSION stage stage_id algorithm level CR LF stage output 1 output stage_id of chosen stage 1 Output on the device algorithm 0 None 1 DSC level Compression level 1 L1 Normal Set the compression level for output 1 to DSC VID COM...

Page 62: ...o switch mode for a layer of followers for a given input signal This is an Extended Protocol 3000 command COMMAND X FOLLOWERS SW MODE direction_type port_type port_i ndex signal_type index layer CR FEEDBACK Get nn X FOLLOWERS SW MODE direction_type port_type port _index signal_type index layer strategy CR LF The following attributes comprise the Input_signal_id direction_type o IN port_type o HDMI...

Page 63: ...port_type2 por t_index2 signal_type2 index2 CR LF The following attributes comprise the output signal ID 1 and input signal ID 1 direction_type o IN o OUT port_type o HDMI o HDBT o ANALOG_AUDIO o TOS o SPDIF port_index 1 signal_type o AUDIO o ARC o CEC index Indicates a specific channel number when there are multiple channels of the same type TP 594Txr Get the audio output source X ROUTE OUT TOS 1...

Page 64: ...ed on the front or rear panel signal_type o VIDEO index Indicates a specific channel number when there are multiple channels of the same type Logical_id CEC logical ID value 1 15 Set the CEC gateway member ID 14 of HDMI 1 input signal X CEC GW MEMBER IN HDMI 1 VIDE O 1 14 CR X CEC GW MEMBER TP 594Rxr Get CEC gateway member ID for a given output signal This syntax uses the new convention of using b...

Page 65: ...ot enough space for data firmware FPGA ERR_FS_NOT_ENOUGH_SPACE 11 Not enough space file system ERR_FS_FILE_NOT_EXISTS 12 File does not exist ERR_FS_FILE_CANT_CREATED 13 File can t be created ERR_FS_FILE_CANT_OPEN 14 File can t open ERR_FEATURE_NOT_SUPPORTED 15 Feature is not supported ERR_RESERVED_2 16 Reserved ERR_RESERVED_3 17 Reserved ERR_RESERVED_4 18 Reserved ERR_RESERVED_5 19 Reserved ERR_RE...

Page 66: ...sured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up th...

Page 67: ... list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback The terms HDMI HDMI High Definition Multimedia Interface and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator Inc All brand names product names and trademarks are the property of their respective owners D R A F T ...

Reviews: