RJ-45 Pinout:
DIP-Switch Settings
For the Ethernet connector, see the wiring diagram
below:
Changes to the DIP-switches only take effect on power-up. After
changing a switch, reboot the device. All DIP-switches are set to Off
(up) by default.
PIN EIA /TIA 568B
PIN
Wire Color
# Feature
Dip-switch Settings
1
Orange / White
1 IR Pass-through
On (down)
– Add IR modulation to the IR output
signal (applicable only when the IR port is
connected to an IR emitter cable).
Off (up)
– Pass-through the IR signal (default)
to the IR port via an IR cable.
2
Orange
3
Green / White
4
Blue
5
Blue / White
The IR Pass-through DIP-switch setup depends on the IR
control connectivity application and should be set to either Off
or On to ensure that the IR-controlled device responds to the
IR controller.
6
Green
7
Brown / White
8
Brown
2 Range mode
On (down)
– Enable extra-range.
Off (up)
– Disable extra-range (default).
Note that range mode affects the HDBT input only.
3 Audio
de-embedding
On (down)
– Disable audio de-embedding.
Note that the audio output port is muted.
Off (up)
– Enable audio de-embedding to the
analog audio output port (default).
4 Reserved
N/A
For optimum range and performance use the recommended Kramer cables available at
www.kramerav.com/product/VM-214DT
Step 5: Connect the power
Connect the power cord to
VM-214DT
and plug it into the mains electricity.
Safety Instructions
Caution:
There are no operator serviceable parts inside the unit.
Warning:
Use only the power cord that is supplied with the unit.
Warning:
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
Warning:
Disconnect the power and unplug the unit from the wall before installing.
See
for updated safety information.
Step 6: Operate the VM-214DT
Web pages:
RS-232 and Ethernet:
RS-232/Ethernet
Baud Rate:
115,200
Parity:
None
Data Bits:
8
Command Format:
ASCII Protocol 3000
Stop Bits:
1
Example (Route input 1 to output 1):
#ROUTE 1,1,1 <cr>
Ethernet Parameters
IP Address:
192.168.1.39
Subnet Mask:
255.255.0.0
Default UDP Port #: 50000
Default Gateway: 192.168.0.1
Full Factory Reset
Front Panel
Buttons:
Front panel buttons: power off the device, press and hold the
RESET button for 3 seconds while powering the device, and
then release.
Protocol 3000:
“#factory” command.
Web pages:
In the Device Settings page, click Reset.