Defining CEC Functionality
Define whether the unit automatically sends CEC on/off commands to the display (default) or
whether it passes CEC commands from the source to the display (see
To define the CEC behavior:
1. Click
Advanced
on the Navigation List.
The Advanced page appears.
2. Define Output CEC Bypass from the drop-down box:
▪
Off
– Automatically send CEC commands to shut down the output display after a
timeout period when no input signal is found and to power up the display when the
input returns.
▪
On
– Pass CEC commands from the source to the display.
CEC functionality is defined.
Defining the TOGGLE Pin Behavior
VP-427X2
enables defining the function of the REMOTE pin
on the rear panel.
To configure the TOGGLE pin
Connecting the Remote Control Switches
:
1. Click
Advanced
on the Navigation List.
The Advanced page appears.
2. Select the TOGGLE pin configuration from the drop-down box:
▪
Edge = (toggle on/off).
▪
Input Select.
▪
GND=Off / Hi=On
▪
GND=On / Hi=Off
▪
Hi=Off
▪
Hi=On
▪
GND=Off
▪
GND=On
TOGGLE pin button is defined.