Kramer Electronics Ltd.
VP-444
– Using Embedded Web Pages
27
2. In the On Output area, click one of the following for each of the outputs:
▪
Input
– signal only sent with HDCP encryption when the input includes HDCP
encryption.
▪
Output
– signal is always sent with HDCP encryption when the output supports it,
even if the input does not include encryption.
3. In the On Input area, click
ON
or
OFF
for each of the four inputs to turn on or off the
HDCP encryption for that input.
Managing EDID
VP-444
enables you to individually configure and manage EDID settings for each of the 6
inputs.
To manage EDID:
1. Click
EDID
on the Navigation List.
The EDID page appears.
Figure 25: The EDID Page
2. Under Read from, click the required EDID source or click
Browse
to use an EDID
configuration File.
3. Under Copy to, click the inputs to copy the selected EDID to.
The Copy button is enabled.
4. Click
Copy
.
The selected EDID is copied to the selected inputs and the Copy EDID Results message
appears.