VS-1616D - Configuring the Number of Installed Input and Output Ports
10
Configuring the Number of Installed Input
and Output Ports
After installing or removing a module you need to set the number of input and
output ports so that the
VS-1616D
recognizes the new configuration. Refer to
Section 5.1
for an explanation of port numbering before setting the number of input
and output ports.
To set the number of input or output ports:
1. Press ESC, ENT and LOCK together.
The following is displayed:
Configuration Device
2. Press ENT.
The following is displayed:
Test Board: 0 MaxInput:16 MaxOutput:16
The number of input and output ports can only be set in units of two,
for example, 4 x 4, 16 x 4 or 12 x 16.
3. Using the numeric keys, enter the number of input and output ports installed.
The TAKE button flashes.
4. Press TAKE.
The number of installed ports is saved and the display reverts to the
output/input display.
5. Reboot the device by turning the power off and then on again.