– Using the Configuration Menus
29
8. Select the required action or number using the keypad numbers and arrows.
9. Press TAKE to save the change.
The parameter change is not implemented on the system until you press TAKE.
10. Repeat from Step 6 to modify additional parameters.
11. Do one of the following:
▪
Press BREAKAWAY to exit the Config Menu.
▪
Wait approximately 15 seconds for the operation to time out.
▪
Press MENU to exit to the parameter list.
Config Menu
—
Output Load Detection Display
This option displays a list of outputs and indicates which have loads attached to them.
To display a list of outputs and attached loads:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them
2. Press MENU until the following is displayed:
OUT:
01 02 03 04 05 06 07 08 09 10 11
LOAD: o
X
o
o
o
o
X
o
o
o
X
o
indicates that a load is attached and
X
indicates that no load is detected on the relevant
output.
3. Do one of the following:
▪
Press BREAKAWAY to exit the Config Menu
▪
Wait approximately 15 seconds for the operation to time out
▪
Press MENU to move to the next Config Menu option
Config Menu
—
Setting Output Port Parameters
This option sets port-specific parameters. Ports that show an
X
have no parameters available
to modify. Ports that show an
o
have parameters available to modify. The parameters that are
available, such as, audio balance, depend on the type of card installed and whether the card
is an input or an output card. Tables listing output cards and their parameters can be found at
the end of this section.
To set parameters for a port:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them