KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting a Control Interface
20
To connect an RS-485 connector on one unit to an RS-485 connector on one
or more other switchers (from the series of 16x16 matrix switchers), as
Figure 11
illustrates:
1. Connect the “+” PIN on the first unit to the “+” PIN on the second unit or
other unit
2. Connect the “-” PIN on the first unit to the “-” PIN on the second unit or
other unit
3. If shielded cable is used for an RS-485 connection, connect the shield to the
Ground PIN.
For details about how to configure the vertical sync (if required), refer to
section
9.3
and
Figure 17
in section
11.3.1
.
Figure 11: Connecting the RS-485 Connectors
Figure 12
illustrates the RS-485 line that connects:
•
To the PC via a Kramer Tools
VP-43xl
Interface Converter
(connect the PC’s 9-pin D-sub COM port to the “RS-232 in” 9-pin
D-sub (F) port on the
VP-43xl
. Next, connect the RS-485 port on
the
VP-43xl
to the RS-485 ports on the unit by connecting the
“A” terminal of the
VP-43xl
to the “+” terminals of the switchers,
and “B” to “-” terminals)