KRAMER: SIMPLE CREATIVE TECHNOLOGY
Flash Memory Upgrade
48
dynamically inside the blue line. The displays on the unit show the
messages:
Transfer may take minutes
Please, wait…
Σ
=080756
1
12. Observe the PC monitor and the unit
MATRIX
and
STATUS display
s. After
about 30 seconds, the program installation completes, the color of the
Send
button ceases to be red and the numbers inside the blue line disappear. The
displays on the unit show the messages:
Program replaced
successfully!
Σ
=16608D
16608D
13. After about 3 seconds, the displays show the messages:
Turn unit OFF, reconnect
cables and turn ON
Σ
=16608D
16608D
14.
Verify that the checksum (for example,
Σ
=16608D) is the same on both
lines
.
If not, repeat the firmware upgrade process from the beginning.
15. You have successfully replaced the previous program and upgraded to the
latest Kramer firmware version.
Turn the
POWER
switch on the unit off.
Reconnect the RS-232 IN and RS-232 OUT rear panel port connections (as
applicable).
Turn the
POWER
switch on the unit on again.
Observe the new version number that shows in the
STATUS display
.
Go to the Menu and restore your specific settings. Prepare and store all
necessary setups.
1 Shows the dynamic progress upgrade of the checksum