MENU Commands
49
49
connector (this signal should be properly terminated via the
TERM button
1
•
INT# 1
(internal sync) - switching occurs during the vertical
interval of the video reference signal connected to IN # 1
)
Setting the
VS-162V
unit as a Large Matrix
1
(instead of as a Stand-Alone
UNIT) provides a choice of 4 SWITCHING METHOD settings:
•
NoVIS
,
EXT
or
INT# 1
(as described above)
•
MTX
(SYNC from Matrix) - the vertical interval of the video
reference (selected on one unit in the Large Matrix system) is
present on the “SYNC” RS-485 terminal block connector
2
To choose the MTX (SYNC from Matrix) setting
. This
reference signal applies to all switchers in the multi- switcher
system and facilitates switching all
VS-162V
units simultaneously
3
Figure 21
as shown in
:
•
Connect the RS-485 terminal block connectors
4
•
Connect and set the video reference signal on one of the video
units to EXT (external sync) or INT# 1 (internal sync)
between each
switcher in the multi- switcher system
•
Set the video reference on the other video units to the MTX
(SYNC from Matrix) setting
Figure 21: Choosing the MTX (SYNC from Matrix) Setting
1 Item 3 in
Figure 1
2 Item 5 in
Figure 1
3 This sets the matrix sync configuration from another (Master) machine
4 Via a straight connection of all 4 PINS