background image

 

 

Step 4:  Connect the inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

VS-211X

. For best results, we recommend that you 

always use Kramer high-performance cables to connect AV equipment to the 

VS-211X

.

 

VS-211X

 and 

VS-411X

 are identical 

except for the number of inputs. 

 

Setting the DIP-Switches 

DIP-switches 1, 2 and 3 are set to ON (down) by default and DIP-switch 4 is always set to OFF (up).  
DIP-switch changes take effect immediately. 

Feature 

Dip-Switch Settings 

 

Switching Mode 

OFF (up) 

– Manual mode. 

ON (down) 

–Auto-switching mode. 

 

Auto-switching Mode 

OFF (up) 

– Priority switching mode: the device

 

switches the source with the 

highest priority to the output. 
ON (down) 

– Last connected switching mode: the last detected active source is 

auto-switched to the output. 

EDID lock 

Off (up) 

– EDID Locked.  

On (down) 

– EDID parameters are passed-through. 

 

Reserved for Factory Use  It is mandatory to keep set to OFF (up). 

 

For optimum range and performance use the recommended Kramer cables available a

www.kramerav.com/product/VS-411X

 

Step 5:  Connect the power 

Connect the power cord to 

VS-211X

 / 

VS-411X

 

and plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information).

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the 

terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

 

  