KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using the Configuration Menus
20
The display reverts to the output/input display showing that the selected input
is switched to all outputs.
8.1.2 Setup Menu—3: outXX=>OFF, Turning an Output Off
This option turns an output off.
To turn an output off:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 3 (OFF).
The following is displayed:
out__ => OFF
3. Using the numeric keys, enter the output to be turned off.
The TAKE button flashes.
4. Press TAKE.
The selected output is turned off.
The display reverts to the output/input display showing that the selected
output is turned off with the input being blank.
8.1.3 Setup Menu—7: EDID, Assignment to an Input
This option assigns an EDID to an input.
Each input on the
VS-3232DVI
has a factory default EDID loaded (see
Section 13
). The EDID for each input can be changed independently by uploading
an EDID binary file to each input via the RS-232 port using Kramer EDID Sender
software
1
To assign an EDID to an input:
.
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID).
The following is displayed:
SETUP EDID
ENTER to View EDID and Set EDID
3. Press ENT.
The current EDID matrix configuration is displayed.
4. Using the numeric keys, enter the input (in this example, 08) and output (in
this example, 05) from which to read the EDID.
The following is displayed:
00 01 02 03 04 05 06 07 08
05 out05 => in08
The TAKE button flashes.
1 Available for download from
http://www.kramerelectronics.com