5.5  Connecting the REMOTE Connector 

You can force the routing of one of the 2 inputs to the XGA output by remote 

control. To do so, connect the appropriate REMOTE input

 

terminal block 

connector pins to a dry contact switch

1

. For example, as Figure 6 illustrates, to 

route 

REMOTE IN 1

 to the XGA output, connect PIN 1 to the Ground. To route 

REMOTE IN 2 

to the XGA output, connect PIN 2 to the Ground pin. Do not 

connect both the 

REMOTE IN 1

 and the 

REMOTE IN 2 

to the Ground pin 

simultaneously. 

 

 

Route input 1 to the output, by 

attaching PIN 1 to the Ground:

 

 

Route input 2 to the output, by 

attaching PIN 2 to the Ground:

 

 

Figure 6: Remote Terminal Block Connector 

When both XGA INPUT 1 and XGA INPUT 2 are connected, the signal from 

XGA INPUT 1 routes to the output (factory default). However, you can force 

the routing of XGA INPUT 2 to the output by attaching PIN 2 to the Ground. 

Even if no input is present on XGA INPUT 1, you can force the routing of the 

output from XGA INPUT 1 (displaying a blank screen) by attaching PIN 2 to 

the Ground. 

 

 

 

 

 

 

 

 

 

 

                                                       

 

1  Note  that  the  connection  should  be  permanent,  since  the  WP-211DS  will  revert  to  an  automatic  switcher  when  the 
connection is removed 

Summary of Contents for WP-211DS

Page 1: ...Kramer Electronics Ltd USER MANUAL Model WP 211DS Wall Plate ...

Page 2: ...ors 6 5 3 Connecting the WP 211DS 7 5 4 Operating using the Default Master Source Signal Selection 8 5 5 Connecting the REMOTE Connector 9 6 Technical Specifications 10 Figures Figure 1 WP 211DS Front Panel 3 Figure 2 WP 211DS Rear Panel 4 Figure 3 Example of a Conference Room WP 211DS Installation 5 Figure 4 CAT5 PINOUT 6 Figure 5 Example of a WP 211DS Installation 7 Figure 6 Remote Terminal Bloc...

Page 3: ...o the user manual Caution No operator serviceable parts inside unit Warning Use only the Kramer Electronics input power wall adapter that is provided with this unit1 Warning Disconnect power and unplug unit from wall before installing or removing device or servicing unit 1 For example model number AD2512C part number 2535 000251 ...

Page 4: ...al Use Kramer high performance high resolution cables4 3 Overview This section describes The power connect feature see section 3 1 Using shielded twisted pair STP unshielded twisted pair UTP see section 3 2 A summary of the WP 211DS see section 3 3 Recommendations for achieving the best performance see section 3 4 3 1 About the Power Connect Feature The Power Connect feature lets you power a trans...

Page 5: ...ed twisted pair UTP cable is preferred However the unshielded twisted pair UTP cable should be installed far away from electric cables motors etc which are prone to create electrical interference 3 3 About the WP 211DS Your Kramer WP 211DS Wall Plate available in 4 versions one for Belgium one for Germany one for England and the rest of Europe and one for the USA is a high performance 2x1 automati...

Page 6: ...n in signal quality due to poor matching and elevated noise levels often associated with low quality cables Avoiding interference from neighboring electrical appliances that may adversely influence signal quality and positioning your WP 211DS away from moisture excessive sunlight and dust 4 Your WP 211DS Figure 1 and Table 1 define the front panel of the WP 211DS Figure 1 WP 211DS Front Panel ...

Page 7: ... screen1 10 POWER LED Lights when receiving power 11 LOOP HD15F Connector For XGA looping to increase output availability for example to connect to an additional monitor Figure 2 and Table 2 define the rear panel of the WP 211DS Figure 2 WP 211DS Rear Panel Table 2 WP 211DS Rear Panel Features Feature Function GND PIN Connect to the Ground 12 POWER SUPPLY Terminal Block Connector 12V PIN Connect t...

Page 8: ...lowing terminal block output connectors to the pre installed wiring in the wall box opening1 the 1 XGA OUT RGBHV 10 PIN It connects to the XGA acceptor for example a projector 2 AUDIO OUT 3 PIN It connects to the audio acceptor for example a pair of speakers 3 CAT5 OUTPUT 8 PIN It connects to the CAT5 line input 4 REM 3 PIN It connects to the remote connector see section 5 5 In addition Connect th...

Page 9: ...e 4 define the UTP CAT5 PINOUT using pin to pin wiring to connect the WP 211DS output to the TP 120 input Table 3 CAT5 PINOUT TP 120 CAT5 INPUT WP 211DS CAT5 OUTPUT PIN Wire Color PIN Wire Color 1 BLUE 1 BLUE 2 BLUE 2 BLUE 3 GREEN 3 GREEN 4 12VDC 4 12VDC 5 GND 5 GND 6 GREEN 6 GREEN 7 RED 7 RED 8 RED 8 RED Figure 4 CAT5 PINOUT ...

Page 10: ...ribes 3 Connect a second computer graphics source to the XGA INPUT 2 HD15F connector and to the AUDIO IN 2 3 5mm mini jack for example using a Kramer C GMA GMA cable1 4 Connect an additional display to the LOOP HD15F connector optional Figure 5 Example of a WP 211DS Installation 1 XGA HD15M Audio jack to XGA HD15M Audio jack not supplied The complete list of Kramer cables is on our Web site at htt...

Page 11: ... the default the WP 211DS routes the signal from the source at XGA INPUT 1 and AUDIO IN 1 to the XGA OUT and the AUDIO OUT connectors A signal from the XGA source at XGA INPUT 1 input when IN 1 is selected as the default while routing the signal from the XGA source at XGA INPUT 2 the WP 211DS will reroute the signal from the XGA source at XGA INPUT 1 and AUDIO IN 1 to the XGA OUT and the AUDIO OUT...

Page 12: ... pin simultaneously Route input 1 to the output by attaching PIN 1 to the Ground Route input 2 to the output by attaching PIN 2 to the Ground Figure 6 Remote Terminal Block Connector When both XGA INPUT 1 and XGA INPUT 2 are connected the signal from XGA INPUT 1 routes to the output factory default However you can force the routing of XGA INPUT 2 to the output by attaching PIN 2 to the Ground Even...

Page 13: ...IDEO 1Vpp XGA AUDIO 4dBm BANDWIDTH 3dB VIDEO 260MHz XGA AUDIO 20kHz DIFF GAIN 0 05 XGA DIFF PHASE 0 1 XGA K FACTOR 0 3 XGA S N RATIO VIDEO 74dB AUDIO 80dB CROSSTALK all hostile VIDEO 59dB 100MHz CONTROLS Contact closure remote control input default selection switch Image off button COUPLING VIDEO DC AUDIO DC AUDIO THD NOISE 0 017 AUDIO 2nd HARMONIC 0 005 POWER SOURCE 12 VDC 330mA DIMENSIONS Belgiu...

Page 14: ...original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warr...

Page 15: ...r the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing ...