Although the lining has an inactivating effect, Krantz recommends the use of personal protective
equipment consisting of disposable gloves and an FFP2 mask.
Since the sound-absorbing panels within the raw gas chamber are also lined in order to have an
inactivating effect, they should be replaced whenever the HEPA filter element is changed.
The lined sound absorption panels of the raw gas chamber are always included in the shipment of the
HEPA filter element.
Carry out the following steps to change the HEPA filter element:
Shut off the device. See section 8.4.
Open the lower front cover by loosening the 6 hexagon socket captive screws M6.
Hold the front cover against unintentional folding over or falling down.
After loosening the front cover, set it aside carefully.