44
Figure 5. Coaxial system output method
Gas stove are designed for a specific combustion air supply. The chimney system used to connect the
Freestanding STOVE AB series is based on elements consisting of two coaxial conductors, wherein
the outer diameter of 150 mm is responsible for providing air to the combustion chamber and the
internal diameter of 100 mm for the discharge of exhaust gases. The concentric line must end with a
special cap to allow proper operation of the system.
The coaxial cable should be terminated with a special thimble allowing for proper operation of the
system. All system components must have the required approvals and CE certificates. Freestanding
gas stove AB Series has been tested using a coaxial - air combustion system. In the event of con-
densate in the air-flue pipe, the fitter should apply a drainage element (droplet eliminator).