44
Figure 5. Coaxial system output method
Gas stove are designed for a specific ombustion air supply. The chimney system used to connect
the Freestanding STOVE
PANTHER MERLOT
series is based on elements consisting of two coaxial
conductors, wherein the outer diameter of 150 mm is responsible for providing air to the
combustion chamber and the internal diameter of 100 mm for the discharge of exhaust gases. The
concentric line must end with a special cap to allow proper operation of the system.
The coaxial cable should be terminated with a special thimble allowing for proper operation of the
system. All system components must have the required approvals and CE certific
tes. Freestanding
gas stove
PANTHER MERLOT
Series has been tested using a coaxial - air combustion system. In the
event of con-densate in the air-flue pip
, the fit
er should apply a drainage element (droplet
eliminator).
Summary of Contents for PANTHER MERLOT
Page 4: ...4 Fig 1 PANTHER MERLOT estufa de gas Fig 2 Dimensiones estufa a gas PANTHER MERLOT ...
Page 12: ...12 Fig 10 Desmontaje de las puertas Fig 9 Retirada de la cubierta inferior ...
Page 39: ...39 Rys 1 PANTHER MERLOT GAZ gas stove Rys 2 Dimensions Freestanding PANTHER MERLOT EN ...
Page 47: ...47 Figure 10 Removal of the doors Figure 9 Removal of the bottom cover ...
Page 50: ...50 Fig 12 How to install a settler if required ...
Page 72: ......
Page 74: ...74 Fig 1 PANTHER MERLOT GAZ à gaz Fig 2 Dimensions du chauffage à gaz PANTHER MERLOT ...