52
Figure 14. Adjustment method of the discharge pressure
Figure 15. Adjusting method for the minimum flame heig t of the main burner
WARNING!!!
Locking the pressure regulator is realized by the maximum tightening its adjusting screw.
Adjusting the minimum flame height of the main burner
1.
Set the main valve knob to „
OFF
”. Turn it clockwise until valve opening.
2.
The minimum flame heig
t of the main burner can also be adjusted by tightening the adjusting
screw (Fig. 13). The adjustment screw is set so as to provide the maximum flame heig
3.
Turnthescrewclockwisetoreducetheminimumheightoftheflam
.
4.
Depending on the version of the controller, the minimum flame heig
t of the main burner can
be set at the factory by the manufacturer or can be adjusted by the installer.
If, despite the adjustment, the desired pressure was not achieved, check the pressure of the gas sup-
plied using a gauge connected to the measurement point of the input pressure. If the inlet pressure is
within the normal range, replace the controller; otherwise take the necessary steps to ensure proper
gas pressure.
Summary of Contents for PANTHER MERLOT
Page 4: ...4 Fig 1 PANTHER MERLOT estufa de gas Fig 2 Dimensiones estufa a gas PANTHER MERLOT ...
Page 12: ...12 Fig 10 Desmontaje de las puertas Fig 9 Retirada de la cubierta inferior ...
Page 39: ...39 Rys 1 PANTHER MERLOT GAZ gas stove Rys 2 Dimensions Freestanding PANTHER MERLOT EN ...
Page 47: ...47 Figure 10 Removal of the doors Figure 9 Removal of the bottom cover ...
Page 50: ...50 Fig 12 How to install a settler if required ...
Page 72: ......
Page 74: ...74 Fig 1 PANTHER MERLOT GAZ à gaz Fig 2 Dimensions du chauffage à gaz PANTHER MERLOT ...