The main burner does
not ignite
• Make sure the holes of the main burner are not blocked.
• Make sure the manual mode dial is set to the „ON” position.
• Check the control flame i tensity.
• Make sure the control flame ontrol is not blocked with decorations.
• Make sure the thermocouple sensor is operating and properly connec-
ted to the gas control module.
• Make sure the flame ontrol is capable of heating the temp. sensor.
The main burner
automatically turns off
after the stove reaches a
certain temperature
• Check the thermostat setting.
There is sediment depo-
sited on the glass
• Make sure the holes of the main burner are not blocked.
• Check that the gas pressure in the installation is correct.
• Check that nothing blocks the chimney system.
The device cannot be
turned off using the
remote control
• Try turning off the bu ner using the switch on the gas control module,
setting it to „O”. If there is no response, replace the gas control module.
• Check the connection between the breaker and the controller.