background image

2

Prior to Installation:

Make sure you have all necessary parts by checking the diagram and parts list. If
any part is missing or damaged, please contact Kraus Customer Service at 800-
775-0703 for a replacement

Turn off the hot and cold water supply at the angle stops and turn on the old
faucet to release any built up pressure. Remove existing faucet. Clean sink or 
countertop to remove any debris, plumber’s putty, or silicone

• •

Place bucket under angle stops. Turn on to flush any debris prior to installing new

 

plumbing. Shut off angle stops 

Pre-drilled hole size requirement: 1-3/8” (min) – 1-1/2” (max)

Max countertop thickness without deck plate: 1-

1/2

Max countertop thickness with deck plate: 1” 

Without deck plate:

With deck plate:

1/16” (1mm) min. 

1-1/2” (38 mm) max

.

Ø 1-3/8” (35 mm) min.

Ø 1-1/2” (38 mm) max

.

1/16” (1mm) min. 

1” (25.4 mm) max.

Ø 1-3/8” (35 mm) min.

Ø 1-1/2” (38 mm) max.

1

2

Designated Mark

Hot

Upward

Black

Cold

1A

1B

2

3

4

5

6

7

G

G

E

E

F

G

G

G

G

F

F

F

E

E

H

E

E

A

A

I

B

J

D

D

C

D

G

Half Moon Locking Nuts

Half Moon Locking Nuts

Rubber Caps

Tools you will need:

Adjustable Wrench  

Safety Goggles

Bucket

Silicone Sealant

6 5/8”

5 4/5”

3/8”

(10mm)

7/8”

19.7

º

(22mm)

8 5/16”

1 1/4-18UNF-2A

(21mm)

10 1/8”

(257mm)

1 3/8”

(35mm)

3 3/4”

(168mm)

(147.3mm)

(96mm)

∅ 

1 3/4”

(

∅ 

45mm)

∅ 

1 15/16”

(

∅ 

50mm)

9/16”-18UNEF

27mm ~ 41.3mm

1 1/16”

  ~ 1 5/8”

∅ 

1 15/16”

(

∅ 

50mm)

12 7/16”

(316mm)

1 5/8”

(42.5 mm Max)

7A

8B

8C

8D

8A

7A

8B
8C

8D

8A

Adjustable wrench

Phillips screwdriver

Tools You Will Need

Hex wrench 

 Silicone Sealant

A

I

D

J

F

B

G

C

H

E

Summary of Contents for Mateo KPF-2620

Page 1: ...INSTALLATION MANUAL KPF 2620 Mateo Single Lever Pull Down Kitchen Faucet www kraususa com I toll free 1 800 775 0703 I 2014 2015 Kraus USA Inc I REV August 25 2015 ...

Page 2: ...elcome any questions or comments you may have and will be glad to assist you in the future For more information about Kraus products please visit our website at www kraususa com Please register your new Kraus product at the following web address in order to activate the warranty and receive the full benefit of customer support www kraususa com registration Sincerely Kraus Customer Service Departme...

Page 3: ...ebris prior to installing new plumbing Shut off angle stops Pre drilled hole size requirement 1 3 8 min 1 1 2 max Max countertop thickness without deck plate 1 1 2 Max countertop thickness with deck plate 1 Without deck plate With deck plate 1 16 1mm min 1 1 2 38 mm max Ø 1 3 8 35 mm min Ø 1 1 2 38 mm max 1 16 1mm min 1 25 4 mm max Ø 1 3 8 35 mm min Ø 1 1 2 38 mm max 1A 2 3 E E F G G G G F F B J D...

Page 4: ... B A C D J F I H G E Diagram and Parts List A Spray Head B Faucet Body C Deck Putty Plate D Base E Spray Hose F Supply Hose G Hot Cold Waterlines H Weight I Quick Connect J Hex Wrench Set J1 2 5mm J2 4mm ...

Page 5: ...4 9 16 24 UNEF 3 8 Compression Check Value 8 7 221mm 2 4 62mm 7 3 186mm 8 2 208mm 15 75 400mm 10 25 260mm 4 31 109mm 10 5 267mm 0 06 1 2 1mm 30mm 1 6 40mm 24 44 620mm 15º Faucet Dimensions ...

Page 6: ...k or countertop Insert base D into hole of deck putty plate C with FR NT facing forward Tighten screws on base D with 4mm hex wrench J until base is secure on deck putty plate C 1 2 Hot Cold 1A 1B 3 4 6 G G E A B J D D C Half Moon Locking Nuts Half Moon Lockin 1 2 1B 4 G C D Half Moon Locking Nuts Installer Tip Rotate the two half moon shaped locking nuts inward before inserting base D into deck p...

Page 7: ...ne by one in large hole of base Align arrow on faucet body B with arrow on base D Attach faucet body B to base D and turn counter clockwise Secure faucet body B by tightening the set screw with 2 5mm hex wrench J D G G G G B D F F F I I E I F E Designated Mark E H Rubber Cap G B D J G Hot Cold Installer Tip Please loosen set screw from faucet body B prior to securing to base D ...

Page 8: ...leaks DO NOT TURN FAUCET ON Attach Quick Connect I to spray hose E Attach the other end onto the supply hose F until you hear a click Installer Tip Tug on the spray hose E moderately to ensure connection is secure Installer Tip Please remove rubber cap from supply hose F prior to installing quick connect I G G Hot Cold E E D G G G B D F F F I I E I F E Designated Mark E H Rubber Cap G G Hot Cold ...

Page 9: ...t Attach weight H on the designated mark on the spray hose E Remove spray head A Hold tip of spray hose E Turn faucet on for 1 minute to flush any debris Reconnect spray head A Designated Mark E E A A H G G Hot Cold E E A A G G Hot Cold E E A A ...

Page 10: ...4 3 11 13 14 12 1 A Index Button B Set Screw 2 Metal Handle 3 Cartridge Cover 4 Locking Nut 5 Cartridge 6 Spray Head 7 Set Screw 8 Quick Connect Assembly 9 Spray Hose 10 Weight 11 Cover Putty Plate 12 Base 13 Hex Wrench 2 5mm 14 Hex Wrench 4mm ...

Page 11: ...ompletely Cartridge 5 may need to be adjusted or replaced Remove index button 1A Loosen set screw 1B with 2 5mm hex wrench 13 Remove metal handle 2 Remove cartridge cover 3 by hand only Remove locking nut 4 with an adjustable wrench Remove ceramic disc cartridge 5 Check for cracks Hose does not retract Weight 10 may be installed incorrectly Readjust weight 10 on the hose 9 Make sure it is installe...

Page 12: ...with clean water dry with a soft cloth 2 Do not clean with soaps acid polish abrasives or harsh cleaners 3 Do not use cloth with a coarse surface 4 Unscrew the aerator and clean when necessary This installation manual is subject to change without further notice Open Left Hot Water Push ...

Page 13: ... charge or at its option replace any product or part of the product that is deemed defective under normal installation use service and maintenance If Kraus is unable to provide a replacement and repair is not practical or cannot be made in timely fashion Kraus may elect to refund the purchase price in exchange for the return of the product CONDITIONS AND EXCLUSIONS Like other home fixtures Kraus p...

Page 14: ...idental consequential or special damages associated with the return replacement installation or use of your product This includes freight costs cartridge replacement labor travel time lost profit home damages and other contingent liabilities and costs including without limitation costs associated with experts investigations analyses attorneys and other professionals and services The Kraus warranty...

Page 15: ...s USA Inc 12 Harbor Park Drive Port Washington NY 11050 516 801 8955 Proservice kraususa com If you are an Authorized Partner please contact a Partner Support Representative at Kraus USA Inc 12 Harbor Park Drive Port Washington NY 11050 516 801 8954 Partnersupport kraususa com In requesting warranty service please be ready to provide 1 Proof of purchase 2 A description of the problem HELP LINE Our...

Page 16: ...www kraususa com ...

Reviews: