APPENDIX
©2014 Kraus Global Ltd.
Retail CNG Dispenser Manual
Appendix-7
Micro Motion® CNG050 flow meter (continued)
Environmental limits
°
F
°
C
Process fluid
temp. limits
-40 to +257
-40 to +125
Ambient temp.
limits
CSA and MMI
standard
(no approval)
-40 to +140
-40 to +60
ATEX
Humidity limits
5 to 95% relative humidity, non-condensing at
140°F / 60°C
Vibration limits
Meets IEC 68.2.6, endurance sweep, 5 to 2,000 Hz, 50
sweep cycles at 1.0 g
Weight
Sensor with core processor
16 lbs / 7 kg
Sensor with integrally mounted
transmitter
18 lbs / 8 kg
Materials
Wetted parts
(1)
316L stainless steel
Sensor housing
304L stainless steel
Core processor
housing
CF-3M stainless steel or polyurethane-painted
aluminum; NEMA 4X (IP65)
(1) General corrosion guidelines do not account for cyclical stress and therefore
should not be relied upon when choosing a wetted material for your Micro
Motion® flow meter. Please refer to Mic
ro Motion’s corrosion guide for material
compatibility information.