10
Maintenance
Keep all parts clean of dust and debris.
Care and Cleaning
To clean, wipe with a clean rag or blow compressed air on the jig.
Troubleshooting
Problem
Possible Cause
Solution
The cabinet door is not aligned to
the correct overlay.
The support arm is not in the
correct jig setting.
Check the jig setting placement and
realign the cabinet door.
The cabinet door is too heavy for
the jig setting.
Move the support arm up one
setting or add shims.
The support arm is bent or
damaged.
Call Technical Support.
Adjusting for Cabinet Door Weight
While mounting doors that weigh more than 15 lbs., additional adjustment or shims may be
required for proper placement. Do not use with doors that exceed 25 lbs.
Recommended Accessories (Not Included)
Clamp