Foundation 4K UHD Processor RS-232 Feedback
20
Foundation 4K UHD Processor
OVERVIEW
The Foundation 4K UHD Processor is equipped with a system that can report back its operational status via the RS-232 port.
The system reports it’s operational status by transmitting a block of status data. The block is configured as 18, 8 bit words.
The first and last word always contains hexadecimal code 55 to facilitate message framing and synchronization. When the
data block is sent through an RS-232 port, each 8 bit word transmitted will also have 1 stop bit associated with it.
The Status can be activated in 2 ways. The first way is to ask for status to be sent by sending the RS-232 command “STAZ”.
The second way is to enable auto status by sending the RS-232 command “ASTEZ”, Once this command is sent, the
Foundation 4K UHD will transmit a status block whenever the status changes. Auto Status is disabled by sending the RS-232
command “ASTDZ”. Auto Status remains enabled until AC power is removed or turned off.
RS-232 Port Settings
9600 Baud, 8 Data bits, 1 Stop bit, No Parity
Data Format
18 bytes total, first byte and last byte are framing bytes with a value of 0x55
Byte 1: Framing
Value: 0x55
Byte 2: General Status 1
Bit
7
6
5
4
3
2
1
0
User
Mute
Current
Zone
Input
Trigger
Main
Power
Main Power: 1=On
Input Trigger: 1=12V trigger input active
Current Zone: 0=Main zone, 1=Zone 2
User Mute: 1=user mute active
Byte 3: General Status 2
Bit
7
6
5
4
3
2
1
0
Menu
Mode
Auto
Status
Enabled
Tigger 4
On
Tigger 34
On
Tigger 2
On
Tigger 1
On
DSP
Running
DSP Running: 1=both DSPs out of reset
Trigger On 1-4: 1=12V trigger out is on
Auto Status Enabled: 0=Disabled, 1=Enabled
Menu mode: 1=menu is on
Byte 4: Current Source
Bit
7
6
5
4
3
2
1
0
Z2 Src 3
Z2 Src 2
Z2 Src 1
Z2 Src 0
MN Src 3
MN Src 2
MN Src 1
MN Src 0
MN Src 3-0: Main Zone Source value
0 BD1
8 GM1
1 BD2
9 GM2
2 STB1
10 GM3
3 STB2
11 DVR
4 CBL1
12 DVD
5 CBL2
13 CD
6 SAT1
14 DMP
7 SAT2
15 TV
Z2 Src 3-0: Zone 2 Source value