KREMLIN REXSON
- 3 -
N° : 578.008.120-UK-1106
FLUSHING WITH SOLVENT
7 -
Immerse suction rod (L) and the drain rod (O) into the material container.
8 -
Open the air shut off valve (N).
9 -
Open the valve (H) of the pump air equipment to supply the air motor.
Nota :
If the pump air motor is a 5000 version, it needs pilot air to operate. The pump air
equipment supplies pilot air to the air motor. The air supply pressure is adjusted previously in the
factory to 4 bars / 58 psi maximum.
10 - Increase
progressively
the air regulator (D) so that the pump runs slowly (Pressure between 0,5
to 1 bar / 7.25 to 14.503 psi).
11 - Observe the drain (O); air bubbles come out from it. When bubbles no longer come out from it,
shut off the drain valve (N).
PRIMING WITH MATERIAL
12 - Remove the suction rod (L) and the drain rod (O) from the material container and immerse them
in a solvent filled container.
13 - Open the drain valve (N), wait until the material flows out regularly, then shut off the drain valve
(N).
14 - Point the spray gun towards the material container and trigger the spray gun until the material
flows out regularly.
WORK
15 - Reinstall the ring and the aircap on the spray gun.
16 - Adjust air regulator (D) to obtain the appropriate material pressure and flow rate.
17 -
Gradually
open the air regulator (F) to adjust the spraying air to obtain the required spray
pattern.
Nota :
Some of these pumps are not equipped in the intensiv
™
version with the air regulator (F).
A spraying air kit can be mounted on the pump air equipment in order to supply compressed air to the
spray gun if it is necessary.
2-2 PUMP SUPPLIED IN FILLING (CIRCULATING)
Interconnect the pump fluid inlet with the circulating supply hose and start up the pump as it is specified
previously.
If the pump is a FLOWMAX ® one :
WARNING:
Fluid section filling pressure :
2 bar / 29 psi maximum
WARNING : Do not create overpressure
NEVER use
the pump when
an isolating gate on the supply circuit
(upstream from the
FLOWMAX ® fluid section) is shut :
it would damage the bellows
.
Do not install
a material regulator on the supply circuit or any arrangement that could
perform as a non-return valve.