PRESSURE AND AIR CONSUMPTION OF THE GUNS 

Adjustment of the air pressure with or without gauge at the gun handle 

1 -  

2 - 

3 - 

4 - 

Diagram : 

P 0 : Wall air 
pressure 

Air hose 

P 1 : Pressure 
measured at the 
gun handle when 
operating(the air 
needles are 
open) 

M 22 P Basik 
gun 

1

2

3

4

(P0)

(P1)

 

 
 

M 22 G Basik gun + BA 5 aircap  
+ hose, model 7 mm / 1/4" ID, 7.5 m / 25 ft length 

M 22 P Basik gun + BA 3 aircap  
+ hose, model 7 mm / 1/4" ID, 7.5 m / 25 ft length  

 

P 0  

wall pressure 

P 1 

handle pressure 

P 0  

wall pressure 

P 1 

handle pressure 

(bar) (psi) (bar) (psi) (bar) (psi) (bar) (psi) 

3,2 

46 

29 

3,2 

46 

29 

3,8 

55 

2,5 

36 

58 

2,5 

36 

4,5 

65 

43,5 

4,5 

65 

43,5 

72 

3,5 

50 

73 

3,5 

50 

5,5 

79.8 

58 

5,5 

79.8 

58 

Gravity gun : M 22 G BASIK with 18 BA 5 projector 

 

Air pressure (P1) 

Air flow rate 

Paint flow rate (1) 

Fan width (1) 

 

bar 

PSI 

m3/h 

CFM 

g/mn 

oz/mn 

cm 

 

43.5 

28 

16.5 

280 

9.9 

31 

12.2 

Suction gun : M 22 A Basik with 15 BA 2 projector 

 

Air pressure (P1) 

Air flow rate 

Paint flow rate (1) 

Fan width (1) 

 

bar 

PSI 

m3/h 

CFM 

g/mn 

oz/mn 

cm 

 

43.5 

24 

14.1 

220 

7.8 

24,5 

9.6 

Summary of Contents for M22

Page 1: ...lease read and clearly understand all documents relating to this equipment professional use only PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Page 2: ...mum 6 bar 87 psi Weight 690 g 1 5 lb 1000 g 2 2 lb 530 g 1 1 lb Transfer rate EN 13966 1 Standard 65 2 62 2 63 2 Wetted parts Stainless steel Stainless steel Stainless steel Nozzle Needle Stainless steel Treated stainless steel Cup Poyacetale aluminium Fluid maximum temperature 50 C 122 F Paint viscosity 20 s CA n 4 20 C Gun aircap distance surface to be painted 20 cm 8 AIR AND FLUID CONNECTIONS G...

Page 3: ...odel 7 mm 1 4 ID 7 5 m 25 ft length P 0 wall pressure P 1 handle pressure P 0 wall pressure P 1 handle pressure bar psi bar psi bar psi bar psi 3 2 46 2 29 3 2 46 2 29 3 8 55 2 5 36 4 58 2 5 36 4 5 65 3 43 5 4 5 65 3 43 5 5 72 3 5 50 5 73 3 5 50 5 5 79 8 4 58 5 5 79 8 4 58 Gravity gun M 22 G BASIK with 18 BA 5 projector Air pressure P1 Air flow rate Paint flow rate 1 Fan width 1 bar PSI m3 h CFM g...

Page 4: ... 22 suction version and EN 3 for M 22 pressure version can be fitted on the same on the gun 2 2 Technical features HTi HPA FEATURES E 3 KHVLP aircap EP 3 aircap EN 3 aircap EN 2 aircap Version pressure pressure pressure suction Maximum air supply pressure network 6 bar 87 psi Air pressure at the gun handle From 1 5 to 2 5 bar from 22 to 36 psi From 1 5 to 2 5 bar from 22 to 36 psi From 2 5 to 3 5 ...

Page 5: ...ify that the gun is being operated within the regulatory limitations AIR AND FLUID SUPPLY M 22 gun model HTi HPA Fittings mounted on the gun Air and fluid supply Air Male 1 4 NPS Air hose non static hose HTi minimum 8 mm ID for a 7 5 m 24 6 ft length HPA minimum 7 mm ID for a 7 5 m 24 6 ft length Fluid Male 3 8 NPS For pressure gun HTi HPA Fluid hose minimum 7 mm ID for a 7 5 m 24 6 ft length For ...

Page 6: ... 75 23 13 5 250 8 8 33 13 2 29 28 16 5 250 8 8 34 13 4 2 5 36 33 19 4 250 8 8 35 13 8 3 43 5 38 22 4 3 5 50 42 6 25 HTi with projector model 9 EP 3 Air pressure P 1 Air flow rate Fluid flow 2 Fan width 3 bar PSI m3 h CFM g mn oz mn cm 1 5 21 75 20 2 11 9 250 8 8 31 12 2 2 29 24 5 14 4 250 8 8 30 5 12 2 5 36 29 17 250 8 8 30 5 12 3 43 5 33 2 19 5 300 10 6 32 12 6 3 5 50 37 3 22 300 10 6 32 12 6 HPA...

Page 7: ...ow 2 Fan width 3 bar PSI m3 h CFM g mn oz mn cm 1 5 21 75 16 9 4 107 3 8 19 5 7 7 2 29 19 5 11 5 188 6 6 23 9 2 5 36 23 13 5 198 7 24 5 9 6 3 43 5 26 4 15 5 218 7 7 27 5 10 8 3 5 50 29 7 17 5 207 7 3 28 5 11 2 2 Fluid viscosity 20 s CA n 4 40 centipoises 3 Distance gun aircap surface to be painted 20 cm Optimum fan adjustment ...

Page 8: ...Fluid supply Gravity cup 0 6 liter Weight gun without cup 530 g 1 17 lb Weight gun with cup 690 g 1 52 lb Shades and hydro or solvent based varnishes low viscosity middle viscosity high viscosity Minimum transfer rate EN 13966 1 standard 76 2 74 2 Maximum fluid temperature 50 C 120 F Nozzle needle fluid passage Stainless steel Stainless steel anodized aluminium White cup acetale resin For hydro an...

Page 9: ...ption white cup 0 25 liter PRESSURE AND AIR CONSUMPTION OF THE GUNS Air pressure adjustment with or without gauge at the gun handle 1 2 3 4 Diagram P 0 Air pressure wall Air hose P 1 Pressure measured at the gun handle during the operating air needles open M 22 gun HTi or HPA 1 2 3 4 HTi gun E5 K HVLP aircap hose 8 mm 7 5 m 24 6 ft length HPA gun EN 5 aircap hose 7 mm 7 5 m 24 6 ft length P 0 P 1 ...

Page 10: ...10 7 4 14 200 7 214 7 6 238 8 4 15 245 8 6 229 8 1 256 9 18 260 9 2 275 9 7 282 10 22 284 10 342 12 1 345 12 2 Fan width with nozzle 14 Distance gun aircap surface to be painted cm cm cm 15 cm 30 12 25 10 26 10 20 cm 33 13 28 11 28 11 25 cm 39 15 32 13 30 12 Fluid viscosity 20 s CA n 4 40 centipoises For HTi E 5 K HVLP P 1 2 bar 29 psi For HTi EP 5 P 1 2 5 bar 36 psi For HPA EN 5 P 1 2 5 bar 36 ps...

Page 11: ...G II group II 2 class 2 Surface equipment meant to area where explosive atmospheres due to gas vapours mists are liable to appear from time to time in usual operating G gas On the trigger P air 6 bar 87 psi Gun air supply maximum pressure TYPE xx Gun version On the body INSTALLATION DIAGRAM 2 B A Z1 Z2 Z2 1m 1m 1 3 4 5 A B 1 2 3 4 5 Explosive area area 1 Z1 or area 2 Z2 spraybooth Non explosive ar...

Page 12: ...KREMLIN REXSON N 578 001 120 UK 0910 Nota In some particular cases if the air hose 4 is not conductive the fluid hose 3 must be conductive One of the 2 gun hoses air or fluid must be conductive ...

Reviews: