KREMLIN REXSON
Page 32
Manual : 573.199.112
16. FEATURES - PU 3000 AIRMIX
COMPOSITION
BASE pump
Motor :
3000 PU
Fluid section :
50 cc (standard)
CATALYST pump
Motor :
3000 PU
Fluid section :
50F (Flowmax)
Flushing pump
Option :
Pump depending upon pressure range
TECHNICAL FEATURES
Maximum air supply pressure
6 bar / 87 psi
Maximum fluid outlet pressure of the PU 3000
180 bar / 2610.5 psi
Proportioning ratio / Fluid flow rate
Refer to charts (§ 14 & 15)
Electrical supply of the supply unit
115V / 230V - 10W
Air inlet connection
F 3/4 BSP (air inlet valve)
Fluid outlet connection (mixer)
F 3/4 JIC
The control box of the PU 3000 mixing machine must be installed outside
the spray booth.
SPECIFIC PARAMETERS
Parameters
Description
Factory adjustment
Your adjustments
Section of the A piston
Minimum value: 1 mm2
Maximum value : 99 999 mm2
465
(for fluid section, model 50cc)
Section of the B piston
Minimum value: 1 mm2
Maximum value : 99 999 mm2
470
(for fluid section, model 50F)