KREMLIN REXSON
Page 8
Manual : 573.199.112
3. OPERATING DESCRIPTION
The 2 BASE and CATALYST materials are sent to the mixing machine from 2 pumps.
In production, as well as in regeneration, the machine injects a small volume of catalyst (P-6) in the base
continuous flow.
The PLC continuously checks the mixing ratio and if it notices a fault that it cannot correct, an alarm is
activated. The machine goes into safety mode.
The capacity of the pumps is configured (for the BASE pump : P4 parameter, for the CATA pump : P5
parameter) depending upon the equipment versions.
4. FEATURES
Number of colors : 1
Number of catalyst : 1
Solvent and water-based paints compatibility
Control via a magnet in the control box
Continuous mixing check
Adjustable threshold alarm
Adjustable pot-life indicator
Automatic flushing cycle (time)
VOC display
Consumptions' total indicator : base, cata, solvent,
VOC
Printing (connection to a printer)
Voltage : 230V / 115V - 10W
Air pressure: Mini 4 bar / 58 psi - Maxi 6 bar / 87 psi
Operating pressure :
from 0-6 bar / 0-87 psi or from 6-40 bar / 87-580 psi
for the pneumatic version
from 30 to 180 bar / from 436 to 2610 psi for the
Airmix
version
from 60 to 350 bar / from 870 to 5076 psi for the
Airless version
Adjustable mixing ratio : from 0.6/1 to 20/1 (BASE
volume / CATALYST volume) (from 160% to 5%)
Mixing precision :
1 %
Répeatability :
1 %
Mixed fluid output : refer to § 14 & 15
Maximum operating temperature : 50° C / 122° F
Weight : 115 kg
/ 253.5 lb (Pneumatic version)
187
kg
/
412
lb
(Airmix
version)
217 kg /478 lb (Airless version)
Dimensions :
- Control box : 355 mm x 275 mm x 135 mm
- Fluid frame : 855 mm x 670 mm x 1270 mm
(Airmix
version)
960 mm x 670 mm x 1400 mm (Airless version)
Connections :
Air inlet : F 3/4 BSP (air inlet valve)
Fluid outlet (mixer) :
F 3/4 JIC or assembly of a fitting (
M 1/2 JIC)