1.1
KRIPSOL underwater lights are
manufactured from white, injection
moulded ABS, a material which is
unaltered by physical and chemical
agents, and in fibre-reinforced
polypropylene.
1.2 TECHNICAL CHARACTERISTICS.
KRIPSOL underwater lights are designed
for use a 300 watt parabolic bulb.
They should be used submerged in
fresh or slightly treated water.
We do not recommend that the light unit be
fitted at a depths of more than 1,5 m. For fitting
at greater depths, consult our technical department.
The degree of protection of the
underwater light is IP68. The safety
voltage is 12V (alternating current).
The underwater light has beendesigned
and assenbled according to the international
safety standards CEI 60598-2-18: 1993
(Luminaires for Swimming Pools and
Similar Applications)
This underwater lights is an electrical
receptor class III (S/RBT.MI BT 031, PTO 1.2).
The manufacturer is not responsible
for assembly, installation, operational
start-up, handling or the incorporation
of components that have not been
made in the manufacturer’s facilities.
2.0 INTRODUCTION.
This manual contains the instructions
necessary for the installation, use and
maintenance of KRIPSOL underwater
lights in a swimming pool. In order to
obtain the performances described in
the specifications sheet, all the
recommendations given in this manual
must be complied with and followed
correctly.
This will make it possible to use the lights
in a way that ensures that they are safe
and long lasting.
The equipment supplier will provide the
user with complementary information if he
so requires.
2.1 SAFETY SYMBOLS USED IN THE
INSTRUCTION MANUAL.
Instructions which refer to personal
safety are marked with the following
symbols:
Other instructions relating to operation
which must be complied with in order to
avoid physical damage to the equipment
are marked thus:
2.2 LIABILITY.
Failure to comply with the instructions
given by the manufacturer in this
manual regarding the selection,
handling, installation, operational
start-up and maintenance of the lights
shall free the manufacturer or distribuitor
from any possible liability for accidents
affecting persons or damage to other
installations, and shall, moreover, result
in the cancellation of the guarantee.
2. GENERAL POINTS
ENGLISH
1. DESCRIPTION
8
CAUTION
Caution
General
Hazard
Caution Risk
of Electric
Shock
Standard
DIN 4844-W9
Standard
DIN 4844-W8
Manual proyector:Proyector Plano.qxd 12/12/2011 16:33 Página 8