58
SETTINGS OF FUNCTION PARAMETERS IN MENU
. 4
Low speed.
It is 70% of the maximum speed
Note:
After the quick programming of the drive with
the "AAS" function (auto-adaptation system),
the opening speed is automatically selec-
ted and optimized for the given door. If you
change this speed, re-program the door limit
positions !!!
2
.
2
Distance to start
deceleration for
closing
2.2
Press and hold the SET button for about 6 seconds
until the display shows 0.- then release the button
- use the + button to select 2. then shortly
press the SET button to select this parameter
- the display shows 2.2
- then briefly press the SET button to select
this parameter.
. 1
Deceleration distance before fully closing
for tracks:
SL- 10 [cm], HL-20 [cm], VL-25 [cm].
. 2
Deceleration distance before fully closing
for tracks:
SL- 20 [cm], HL-30 [cm], VL-40 [cm].
. 3
Deceleration distance before fully closing for
tracks:
SL- 25 [cm], HL-45 [cm], VL-50 [cm].
. 4
Deceleration distance before fully closing
for tracks:
SL- 40 [cm], HL-55 [cm], VL-60 [cm].
Note: The given values are approximate and may
vary depending on the size of the cable drums
used.
After the quick programming of the drive by
using the "AAS" function (self-adaptation
system), the distance of the door deceleration
activation is automatically selected and optimi-
zed for the given door.
If you change this
setting, you must re-program the door travel