78
+/-
24V DC electric lock power output,
max load 2A, working time 3 seconds,
the
6.3
function must be on
XHO5
Electric lock power supply output
XH06
Relay outputs
XH09
Inputs for safety systems
Service door security / Amperometric safety bar / Pneumatic slat
NC/COM/NO
relay output, max load
100W, select the function
parameters in the MENU
6.7
NC1/COM1/N01
relay output, max load
100W, select the function
parameters in the MENU
6.6
WT
GND
BR
+12V
GN
Signal
SP15/SD
Safety input for connecting a wicket door sensor in the door
Note 1: SP15 is disconnected, the door drive stops, and all control functions are inactive.
Note 2: The amperometric safety ledge after detecting an obstacle while closing the door, and the door
drive automatically reverses.