background image

Technical Service:

800-417-8405
937-456-8405
technicalservice@hennypenny.com
www.hennypenny.com

Kroger OXE-100 Quick Reference Guide

Basic Operation

Filling the Fresh Oil Tank

Drain Pan Assembly

Product Racking Recommendations

Filter Menu

Preventive Maintenance

Error Codes

The fresh oil tank automatically tops off the oil in the vat when it senses the oil level is 
low. User should add fresh oil to the tank as needed. DO NOT add fresh oil directly to 
the vat. 

1. 

Fill empty vat with new oil to the lower level indicator.

2. 

Turn the POWER switch to the ON position.  

3. 

Allow fryer to heat until set point COOL is reached. 
 

NOTE

• Push the information (i) button to see set point and true temperature of oil. 
• The heat cycles on and off approximately 10 degrees before the setpoint 
temperature to help prevent overshooting the setpoint temperature. 
 

4. 

Press the product button and allow the temperature to reach set point. When 
setpoint is reached, READY displays.

 

Best Practice

: To prevent product sticking to racks, lower empty racks into cooking oil 

and let cool prior to use.

5. 

Slide racks of breaded product into lid carrier. Refer to the Product Racking 
Recommendations section below.

6. 

Lower and lock the lid according to the instructions located on the lid, and then 
press the appropriate product button.

7. 

At the end of the cycle, the alarm sounds and DONE displays.  Press the DONE 
button. The alarm stops. 

8. 

Unlock and raise the lid slowly. Product is very hot.

9. 

Using the rack handles, remove the racks of product from the carrier, starting with 
the top rack.

1. 

Push and hold        until the display reads *MAIN*. 

2. 

Press 

1

 to enter the Filter menu.  

3. 

Use the buttons next to the arrows on the display to access the next set of options. 

4. 

Push the menu button again to cycle to next set of options.

1. QUICK
2. DAILY
3. POLISH

4. DRAIN TO PAN
5. FILL FROM PAN
6. FILL FROM NEW

7. DISPOSE
8. FILL FROM BULK
x. EXIT MENU

Procedure                                     Frequency

Changing of oil.........................................As Required

Changing the filter envelope.....................Daily

Cleaning the vat........................................Daily

Clean slide fillers......................................Weekly

Change Drain Pan O-rings........................Quarterly

Change Fresh Oil Tank O-rings................Quarterly

Code

Cause

Correction

E-4

CPU too hot

Turn switch to OFF position, then turn switch back to 
ON

E-5

Oil Overheating

Have heat circuits and temp. probe checked

E-6 

(A or B)

Temp. probe open 

or shorted

Have temp. probe checked

E-10

High Limit Tripped

Reset the high limit switch located under the control 
board, above the condensation pan

E-15

(C or P)

Drain valve, close 

or open issue

• 

Ensure drain valves are secure

• 

Check for obstructions

Fully loaded with 4-bags
      (all 4 racks used)

4
3
2
1

4-Bags:

  Load all four racks as shown

3-Bags:

  Load racks 1, 2 and 3 only

2-Bags:

  Load racks 2 and 3 only

1-Bag:

  Load rack 2 only

High Limit Reset 

1. 

Slide a filter envelope onto the filter screen so the 

plug is protruding through the hole.

2.  Slide the two handle clamps onto the ends of the  

filter screen assembly with the handles opposite 

sides of the plug.

3. 

Place the filter screen plug up in the bottom of the 

drain pan.

4.  Line up the hole of the pickup tube with the plug 

of the filter screen, then press the tube down. 

5.  Position the pick up tube so that the guides slide 

into the notches located on the hold in the front of 
the drain pan. 

6. 

Press down on the pick up tube to confirm it is 

fully engaged on the filter screen plug and in the 

holder.

7.  Place the crumb catcher onto the handles of the 

clips.

8.  Place the lid onto drain pan.

NOTE

: During assembly, be sure to apply oil to all O-rings to lubricate to help 

prevent tears and loss.

Reviews: