19
4.2
4.1
4
6
5
R
ext
Pulse Output
Common
Screened Cable
OV
88888888
+
_
COUNTER
C
ext
(10 - 100nF if required)
V
ext (Max. 24 V DC)
R
ext >
V
ext
0.15
Fig. 23:
Connection with external voltage source
4.2
4.1
4
6
5
R
ext
(> 800 ohm)
Pulse Output
Common
Screened Cable
OV
88888888
+
_
COUNTER
C
ext
(10 - 100nF if required)
Fig. 24:
Connection using converter internal voltage source
Additional input/output options
No.
Option 4
(2 current,
pulse and
input)
Option 5
(3 current
and
pulse)
Option 6
(3 current
and
input)
Option 7
(3 current
and
alarm
Option B
*
(Current
and
RS485)
Option C
**
(1 Current,
1 Dual
phase pulse
output and
input)
5
Common
(-)
Common
(-)
Common
(-)
Common
(-)
Common
(-)
Common
(-)
6
Current
output (+)
Current
output 1 (+)
Current
output 1 (+)
Current
output 1 (+)
Current
output 1 (+)
Current
output 1 (+)
4
Current
output 2 (+)
Current
output 2 (+)
Current
output 2 (+)
Current
output 2 (+)
TX/RX
Control
Input
4.1
Control
Input
Current
output 3
(+)
Current
output 3
(+)
Current
output 3
(+)
TX/RX
Pulse
Output A
4.2
Pulse
Output
Pulse
output
Control
Input
Alarm
output
(passive)
+5V
Pulse
Output B
*
Refer to separate RS 485 manual
**
Refer to separate manual for this output option.