46
View status message(s) and quit
Button
Display
Description
0.36
kg/min
∇
Measurement mode
The presence of the
∇
marker above Status on the
display indicates the presence of warning messages in
the status list.
↵
CodeE 2
– –
∇
Enter access code for reset/quit menu:
↑
→
↑→
RESET.TOTAL
∇
Totalizer reset menu.
↑
STATUS.LIST
∇
View/Quit Status message menu
→
≡
1 Err
≡
MASS FLOW
∇
This display shows that there is just 1 warning in the list,
in this case MASS FLOW. The
≡
symbols indicate that
this is a new error and not one that has been previously
acknowledged. Use either the
↑
or
→
keys to view other
messages in the list. Otherwise press
↵
to exit.
→
≡
1 Err
≡
QUIT YES
∇
At the end of the message list the QUIT YES prompt is
shown. Selecting YES will clear if possible messages in
the list.
To cancel the operation press
↑
to get QUIT NO and
then press
↵
↵
STATUS.LIST
Assuming the conditions that caused the message have
passed (i.e. mass flow is back within the meter’s range)
then the Status marker,
∇
will disappear.
↵
0.36
kg/min
Assuming RESET YES was selected, the totalisers will
now be cleared.