TECHNICAL DATA
8
87
H250
www.krohne.com
04/2009 - 4000269302 MA H250-R02
H250U - Vertical installation position
Flow direction from top to bottom
Measuring span 10 : 1; flow values 100%
Reference condition:
Water 68
°
F
Air 68
°
F - 14.7 psi
Remarks:
•
The indicated pressure losses are valid for water and air at maximum flow rate.
•
Other flow ranges on request.
•
Conversion to other media or operating data in accordance with VDE /VDI Directive 3513
EN
ASME
Cone
Flow rate
Water [gph]
Flow rate
Air [scfm]
Pressure loss
[psig]
DN15
½
"
K 15.1
17.2
0.99
2.57
K 15.2
29.1
1.55
2.62
K 15.3
44.9
2.48
2.65
K 15.4
68.7
3.72
2.94
K 15.5
111
6.20
3.23
K 15.6
172
9.92
4.26
K 15.7
291
17.4
7.64
K 15.8
396
24.8
12.3
DN25
1"
K 25.1
304
18.6
1.42
K 25.2
476
27.9
1.25
K 25.3
713
43.4
1.35
K 25.4
1189
74.4
1.69
K 25.5
2008
124
2.53
DN50
2"
K 55.1
2378
149
3.23
K 55.2
3963
248
3.38
K 55.3
5548
341
3.53
MA_H250_R02_en_PRT.book Page 87 Tuesday, September 22, 2009 12:26 PM