L
Layer
Thickness of top product. Should be > 50mm or 2" for accurate measurement of level and/or interface. See
following diagram.
Level
Height from the bottom of the tank (user-defined) to the surface of the top product (Tank height – distance).
See following diagram.
Level volume or mass
Total volume filled or total mass of tank contents. See following diagram.
M
Messpuls
Ein kurzer elektrischer Puls geringer Stärke, der vom Messgerät an einer Führung entlang in den Prozess
eingespeist wird, der gemessen werden soll. Dieser Puls wird zum Gerät zurück reflektiert und verarbeitet.
Measurement pulse
A short, low-powered electrical pulse or wave transmitted by the device down a guide to the process being
measured. This is reflected back to the device and processed.
O
Operator
User who has rights to use all menu items in normal mode. Device configuration in program mode is not
allowed.
P
Probe
Either a metallic cable or rod used to guide the measurement pulse to the process.
Probe Length
Ordered length of probe, L, from face of flange to end of probe including short circuit or counterweight
(depending on probe used). See following diagram.
S
Signal converter
A set of electronic components in the device that digitally process the signal received from the returning
measurement pulse.
Supervisor
User with rights to configure the device with a restricted number of menu items in program mode. Device
configuration using service menu items is not allowed.
T
Tank Height
Distance from the face of the flange to the bottom of the tank. See following diagram.
TBF
Tank bottom following. An alternative measurement mode for measuring products with low dielectric
constants. See the measurement modes section.
Summary of Contents for optiplex 1300 c
Page 1: ......
Page 49: ...Handbook OPTIFLEX 1300 C 49 OPTIFLEX 1300 C 1 Volume measurement of liquids...
Page 50: ...Handbook OPTIFLEX 1300 C OPTIFLEX 1300 C 50 2 Volume measurement of solids...
Page 51: ...Handbook OPTIFLEX 1300 C 51 OPTIFLEX 1300 C 3 Mass measurement of liquids or solids...
Page 62: ...Handbook OPTIFLEX 1300 C OPTIFLEX 1300 C 62 Finding the advanced setup menu...
Page 95: ...Handbook OPTIFLEX 1300 C 95 OPTIFLEX 1300 C Note...