background image

 CONTENTS

  

www.krohne.com

01/2014 - 4003344001 - QS OPTIPROBE R02 en

OPTIPROBE

1  Safety instructions

3

2  Installation

4

2.1  General notes on installation ........................................................................................... 4
2.2  Scope of delivery............................................................................................................... 4
2.3  Nameplate ........................................................................................................................ 5
2.4  Installation conditions ...................................................................................................... 6

2.4.1  Inlet and outlet ........................................................................................................................ 6
2.4.2  Mounting position.................................................................................................................... 6
2.4.3  T-section ................................................................................................................................. 7
2.4.4  Vibration .................................................................................................................................. 7
2.4.5  Magnetic field.......................................................................................................................... 7
2.4.6  Pump ....................................................................................................................................... 7
2.4.7  Control valve ........................................................................................................................... 8
2.4.8  Bends ...................................................................................................................................... 8
2.4.9  Open discharge ....................................................................................................................... 9
2.4.10  Temperatures ....................................................................................................................... 9

2.5  Mounting and dismounting............................................................................................. 10

3  Electrical connections

11

3.1  Safety instructions.......................................................................................................... 11
3.2  Connection diagram ....................................................................................................... 11

Summary of Contents for OPTIPROBE

Page 1: ...The cost efficient flow indicator OPTIPROBE OPTIPROBE OPTIPROBE OPTIPROBE Quick Start Quick Start Quick Start Quick Start KROHNE 01 2014 4003344001 QS OPTIPROBE R02 en...

Page 2: ...very 4 2 3 Nameplate 5 2 4 Installation conditions 6 2 4 1 Inlet and outlet 6 2 4 2 Mounting position 6 2 4 3 T section 7 2 4 4 Vibration 7 2 4 5 Magnetic field 7 2 4 6 Pump 7 2 4 7 Control valve 8 2...

Page 3: ...can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation assembly start u...

Page 4: ...s of rough handling Report damage to the carrier and to the local office of the manufacturer INFORMATION Do a check of the packing list to make sure that you have all the elements given in the order I...

Page 5: ...2 Quick Start 3 Factory calibration certificate INFORMATION Look at the device nameplate to ensure that the device is delivered according to your order Check for the correct supply voltage printed on...

Page 6: ...he side of the pipeline 3 Insert the OPTIPROBE perpendicular 4 Insertion length 25mm 5 DN 80mm CAUTION The OPTIPROBE is a sensor which measures flow speed at one point in the pipe In case the flow spe...

Page 7: ...1 2014 4003344001 QS OPTIPROBE R02 en 2 4 3 T section 2 4 4 Vibration 2 4 5 Magnetic field 2 4 6 Pump Figure 2 3 Distance after T sections 1 30 DN Figure 2 4 Avoid vibrations Figure 2 5 Avoid magnetic...

Page 8: ...IPROBE www krohne com 01 2014 4003344001 QS OPTIPROBE R02 en 2 4 7 Control valve 2 4 8 Bends Figure 2 7 Installation before control valve Figure 2 8 Installation in bending pipes Figure 2 9 Installati...

Page 9: ...9 Open discharge 2 4 10 Temperatures Figure 2 10 Installation before an open discharge 1 Process temperature 2 Ambient temperature CAUTION Protect the device from direct sunlight Temperature range C...

Page 10: ...OBE unit as far as possible allowed by the chain 4 Close the valve Remind that the volume above the valve is still pressurized 5 Loosen the bolts 2 in picture below to release pressure 6 Dismount the...

Page 11: ...isconnected Take note of the voltage data on the nameplate DANGER Observe the national regulations for electrical installations WARNING Observe without fail the local occupational health and safety re...

Page 12: ...sis products Products and systems for the oil gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig Krohne Stra e 5 47058 Duisburg Germany Tel 49 203 301 0...