3
ELECTRICAL CONNECTIONS
20
OPTISONIC 7300
www.krohne.com
09/2018 - 4002312802 - QS OPTISONIC 7300 R04 en
100...230 VAC (tolerance range for 100 VAC: -15% / +10%)
100...230 VAC (tolerance range for 100 VAC: -15% / +10%)
100...230 VAC (tolerance range for 100 VAC: -15% / +10%)
100...230 VAC (tolerance range for 100 VAC: -15% / +10%)
•
Note the power supply voltage and frequency (50...60 Hz) on the nameplate.
•
The protective ground terminal PE
PE
PE
PE of the power supply must be connected to the separate U-
clamp terminal in the terminal compartment of the signal converter
24 VDC (tolerance range: -55% / +30%)
24 VDC (tolerance range: -55% / +30%)
24 VDC (tolerance range: -55% / +30%)
24 VDC (tolerance range: -55% / +30%)
24 VAC/DC (tolerance range: AC: -15% / +10%; DC: -25% / +30%)
24 VAC/DC (tolerance range: AC: -15% / +10%; DC: -25% / +30%)
24 VAC/DC (tolerance range: AC: -15% / +10%; DC: -25% / +30%)
24 VAC/DC (tolerance range: AC: -15% / +10%; DC: -25% / +30%)
•
Note the data on the nameplate!
•
For measurement process reasons, a functional ground FE
FE
FE
FE must be connected to the
separate U-clamp terminal in the terminal compartment of the signal converter.
•
When connecting to functional extra-low voltages, provide a facility for protective separation
(PELV) (according to VDE 0100 / VDE 0106 and/or IEC 60364 / IEC 61140 or relevant national
regulations)
3.4 Laying electrical cables correctly
1
Lay the cable in a loop just before the housing.
2
Tighten the screw connection of the cable entry securely.
3
Never mount the housing with the cable entries facing upwards.
4
Seal cable entries that are not needed with a plug.
INFORMATION!
240 VAC + 5% is included in the tolerance range.
Figure 3-5: Protect housing from dust and water