2
DEVICE DESCRIPTION
12
OPTISWIRL 4200
www.krohne.com
08/2016 - 4005002601- AD OPTISWIRL4200 Ex-II2GD R01
Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection
box mounted at side or underneath the flow sensor
box mounted at side or underneath the flow sensor
box mounted at side or underneath the flow sensor
box mounted at side or underneath the flow sensor
Maximum permissible product and ambient temperatures per temperature class in
°
C
Maximum permissible product and ambient temperatures per temperature class in
°
F
Temperature class
T6
T5
T4
T3
T2
T
amb
in
°
C
60
65
60
65
60
65
40
60
65
40
60
65
Nominal size
DN15
…
25
85
65
100
100
135
135
200 200
200
1
240
240
240
1
DN40
…
50
80
65
100
100
135
135
200 200
200
1
240
240
240
1
DN65
…
100
85
65
100
100
135
135
1
200 200
1
200
1
240
240
1
240
1
DN150...300
80
65
100
100
135
135
200 200
200
1
240
240
240
1
1
Permanent service temperature of connecting cable and cable entry min. 80
°
C
Temperature class
T6
T5
T4
T3
T2
T
amb
in
°
F
140 149 140 149 140
149
104
140
149
104
140
149
Nominal size
DN15
…
25
185
149
212
212
275
275
392 392
392
1
464
464
464
1
DN40
…
50
176
149
212
212
275
275
392 392
392
1
464
464
464
1
DN65
…
100
185
149
212
212
275
275
1
392 392
1
392
1
464
464
1
464
1
DN150...300
176
149
212
212
275
275
392 392
392
1
464
464
464
1
1
Permanent service temperature of connecting cable and cable entry min. 176
°
F