W
arning
:
T
he housing must not be used to screw in the instrument
!
A
pplying tightening force on the housing can damage its
internal mechanical parts
.
T
o screw in
,
use the hexagon above the thread
.
4
.
2
M
ounting instructions
T
he vibrating element should protrude into the vessel to avoid
buildup
.
F
or that reason
,
avoid using mounting bosses for
fl
anges and screwed
fi
ttings
.
T
his applies particularly to use
with adhesive products
.
M
ount the instrument in such a way that the tuning fork does
not protrude directly into the
fi
lling stream
.
20°
a.
b.
F
ig
.
3
:
H
orizontal mounting
a
C
onvex mounting
b
C
oncave mounting
I
f such an installation location should be necessary
,
mount a
suitable protective sheet above or in front of the vibrating
element
-
see illustration a
.).
I
n abrasive solids
,
mounting according to illustration b
.
has
proven
.
A
spout forms in the concave protective sheet
preventing wear of the protective sheet
.
S
ocket
F
illing opening
10
OPTISWITCH
3000