3
INSTALLATION
32
OPTIWAVE 7300 C
www.krohne.com
04/2010 - 4000172403 - HB OPTIWAVE 7300 R05 en
How to attach a device with a DIN 11851 connection
•
Make sure the tank connection is level.
•
Make sure that you use the applicable gasket for the connection dimensions and the process.
•
Align the gasket correctly.
•
Lower the antenna carefully into the tank.
•
Turn the nut on the device process connection to attach the device to the tank.
•
Tighten the connection.
i
Refer to local rules and regulations for the correct torque to apply to the connection.
SMS
Equipment needed:
•
Device
•
Gasket (not supplied)
•
SMS nut
Figure 3-19: DIN 11851 connection
1
Tank socket
2
Nut for DIN 11851 connection
Figure 3-20: SMS connection
1
Tank socket
2
Nut for SMS connection
HB_OPTIWAVE7300_en_100430_4000172403_R05_D6B.book Page 32 Thursday, May 6, 2010 6:14 PM