3.7.5 How to turn or remove the signal converter
How to turn the signal converter
•
Loosen the housing locking screw
1
with a 5 mm Allen wrench.
•
Turn the housing to the correct position.
•
Tighten the housing locking screw.
How to remove the signal converter
•
Loosen the housing locking screw
1
with a 5 mm Allen wrench.
•
Lift the housing.
•
Tighten the housing locking screw
1
.
How to attach the signal converter
•
Loosen the housing locking screw
1
with a 5 mm Allen wrench.
•
Attach the housing to the flange system
2
.
•
Tighten the housing locking screw
1
.
INFORMATION!
The converter turns 360
°
.
Figure 3-23: How to turn or remove the signal converter
Tool: 5 mm Allen wrench
CAUTION!
If you remove the housing, put a cover on the wave guide hole in the flange assembly
2
.
HB_OPTIWAVE7300_en_100430_4000172403_R05_D6B.book Page 35 Thursday, May 6, 2010 6:14 PM