4
START-UP
30
OPTIWAVE 7300 C
www.krohne.com
04/2009 - 4000050002 - QS OPTIWAVE 7300 R05 en
Start-up
4.1 Start-up checklist
Check these points before you energize the device:
•
Are all the wetted components (antenna, flange and gaskets) resistant to the product in the
tank?
•
Does the information on the signal converter nameplate agree with the operating data?
•
Did you correctly install the device on the tank?
•
Do the electrical connections agree with the national electrical codes?
4.2 Operating concept
You can read measurements and configure the device with:
•
A digital display screen (optional).
•
A connection to a system or PC with PACTware
™
. You can download the Device Type
Manager (DTM) file from the internet site
•
A connection to a system or PC with AMS
™
. You can download the Device Description (DD)
file from the internet site.
•
A connection to a HART
®
Handheld Communicator.
DANGER!
Before you energize the device, make sure that the supply voltage and polarity are correct.
DANGER!
Make sure that the device and the installation agrees with the requirements of the Ex certificate
of compliance.
QS_OPTIWAVE7300_en_090528_4000050002_R05_web.book Page 30 Friday, May 29, 2009 4:01 PM