UFM
3030
21
3.07.09
ERR LIMIT
Error limit in % of measured value for plausibility filter on the sensor
paths.
3.07.10
CNT DECR
Counter decrement setting for plausibility filter
3.07.11
CNT LIMIT
Counter limit for plausibility filter
When "0" is set, the plausibility filter will become inactive
Range: 0 through 1000
Factory setting: 0
3.09.00 COMMUNIC Submenu
3.09.00 Communication
3.09.01
PROTOCOL
Communication protocol
OFF (no communication)
HART (HART)
PROFIB PA (PROFIBUS PA)
3.09.02
HART ADDR
HART address
Range: 00 through 16
3.09.03
PP/FF ADDR
PROFIBUS PA/FOUNDATION Fieldbus address
Range: 000 through 126
4.00.00
PARAM ERR
Main menu 4.00.00 Parameter error
4.01.00
FLOW VELOC Volume flow velocity (v) value incorrect. The flow speed is
calculated from the full scale volume flow and the meter size.
Ensure condition 0.5 m/s
≤
v
≤
20 m/s (1,5 to 66 feet/s) is met!
4.01.01
FULL SCALE
Full-scale value for 100% volume flow rate, see Function 3.01.01
4.01.02
METER SIZE
Meter size, see Function 3.01.08
4.02.00
CURR OUTP
Current output range incorrect. Setting for 100% is compared with
setting for 0%. Ensure condition 100 pct-0 pct
≥
4 mA is met!
4.02.01
RANGE
Range of current output, see Function 3.04.03
4.02.02
0 pct
Current value for 0% scale, see Function 3.04.04
4.02.03
100 pct
Current value for 100% scale, see Function 3.04.05
4.03.00
LF CUTOFF
Low-flow cut-off range incorrect: If low flow cut-off is set to on, the
value for CUTOFF-OFF is compared with the value of CUTOFF-ON
on.
Ensure condition CUTOFF-OFF – CUTOFF-ON
≥
1% is met!
4.03.01
LF CUTOFF
Low-flow cut-off, see Function 3.01.05
4.03.02
CUTOFF ON
Cutoff “on” value, see Function 3.01.06
4.03.03
CUTOFF OFF
Cutoff “off” value, see Function 3.01.07
4.04.00
ENERGY
Full scale value for heat energy rate (E) incorrect. The fullscale
value is compared with the maximum value that can be measured
and should meet the condition: Emax < E fullscale < Emax/1000
The maximum value that can be measured is at maximum flow and
200° C temperature difference.
4.04.01
HEAT FS
Full-scale value for 100 % heat energy rate, see Function 3.02.12
4.05.00
PULSE/VOS
Unit of pulse output for velocity of sound function incorrect
Ensure "PULSE RATE" is selected for "VOS"!
4.05.01
PULS FUNCT
Function of pulse output, see Function 3.05.01
4.05.02
PULSE OUTP
Unit of pulse output, see Function 3.05.07
4.06.00
VOS
Velocity of sound range incorrect:
Ensure condition MAX VOS
−
MIN VOS
≥
1 m/s (3.3 feet/sec) is
met!
4.06.01
MIN VOS
Minimum velocity of sound, see Function 3.01.11
4.06.02
MAX VOS
Maximum velocity of sound, see Function 3.01.12
4.07.00
PULSE OUTP
Pulse output frequency value (f) incorrect. The max frequency is
calculated from the pulse/unit setting and the max value of the
measured value.
Ensure condition 1 pulse/hr
≤
f
≤
2000 pulse/s is met.