OPERATION
6
49
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
6.3.3 Access control
Service and test
Service and test
Service and test
Service and test
A0
Simulate outputs
0
Off
A1
Reset all counters
88888
Confirm
A2
Flow verification on site
0
Off
A3
Add-on communication
0
Off
Battery
Battery
Battery
Battery
B0
Battery type
2
Internal single batteries
B1
Battery capacity
038.00
38 Ah
B2
Reset battery lifetime counter
0
Confirm
B3
Modbus operation at power
failure
0
Off
Modbus RS485
Modbus RS485
Modbus RS485
Modbus RS485
C0
Modbus slave adress
001
Value to be programmed
(1 to 247)
C1
Baud rate
9.6
9600 baud
C2
Parity rate
0
Even
C3
Register format
1
Big endian
C4
Transmission delay
50
50 ms
C5
Stop bits
1
1 Stop bit
C6
User application name
00000
To be set
C7
RS485 bus termination
0
No RS485 termination
C8
Reception interval
0
Set (0-3600 sec)
No.
Function
Options
Description
1
Access control
0 = Full menu access (default)
If set to 1, access to the program-
ming mode is blocked. To reset
access to the menu please refer to
Reset full access to the menu
on
page 45.
1 = Menu access blocked
Fiscal metering / Custody
transfer