Mode display

The mode display is used to show error codes for testing and service purpose, and for 
remote control programming. The Value display will show values according to the selected 
mode in the Mode display. You may use the Mode button to toggle between the different 
mode settings in the Mode display. 

The degausser operates with 3 different values in the Mode display: Gauss, Ampere and Volt. 
The following matrix will guide you through the different options in the Mode display:

Considerations

The Ontrack Eraser Degausser is designed to erase hard drives and tapes. The following are 
some considerations when erasing modern hard drives and tapes. 

There are two important things to consider when erasing modern drives with a degausser. 
The first is the so-called coercivity of the media used in the drive, and the second is the 
design and geometry of the drive.

Some combinations of coercivity and design/geometry are harder to erase than others.  
 Typically combinations with high coercivity media, many platters, and large form factors 
are hard to erase. Furthermore, the media coercivity is one parameter which drive 
 manufacturers constantly increase to get higher storage capacity.

Maintenance

The Ontrack Eraser Degausser is designed to require only a minimum of maintenance, and 
the degausser has a built in diagnostics system to ensure that the required magnetic field 
strength is always produced. If the diagnostics procedures detect a problem, it will show so 
on the front panel indicators.

In case the degausser needs service, please contact your nearest Kroll Ontrack office. Do not 
perform the service by yourself. If doing so, you will void the warranty.

Although no user calibration is required, the calibration of the diagnostics system should be 
checked every 2 years. This can be done using a standard gauss meter. 

Safety issues

The degausser will produce a very strong field in a limited area. However, there will always 
be some leakage of the field outside the focus area, which may influence the  surroundings. 
For anyone not comfortable with exposure to magnetic fields, we recommend to use 
the  remote control. Since the Degausser produces a DC field, it exerts force on  magnetic 
 materials and it may accelerate metal objects. Therefore, the degausser must not be 
 operated when there are small loose objects lying in the erase area. Also never operate the 
degausser while holding metal objects in your hands close to the erase area. 

It’s recommended to unload the capacitors before transporting or servicing the degausser. 
Push Mode button until the display indicates Test mode. Hold the Mode button until Test 
starts to flash. Start one erase cycle by pushing the Operat button to unload the capacitors. 
Turn off the power.

Summary of Contents for Eraser Degausser 3.0

Page 1: ...Ontrack Eraser Degausser 3 0 User s Guide...

Page 2: ...ck Eraser Degausser is certified by the Norwegian authorities NSM Nasjonal Sikker hetsmyndighet and British CESG Ontrack Eraser Degausser is also recommended by Ger man BSI Ontrack Eraser is a product...

Page 3: ...circuiting the other one might get over voltage and cells can start to leak some gas The gas is easy to smell Turn off the degausser and ventilate the room properly The gas is potentially harmful wit...

Page 4: ...n of the Mode button and the Mode display is provided on page 10 The active erase area is located at the front of the degausser Within the active erase area the magnetic field is strongest and the uni...

Page 5: ...oo high the Operate display will show Temp The degausser will turn into a normal operate mode once the temperature returns to a normal Operating guideline for the Ontrack Eraser Degausser The followin...

Page 6: ...Mode display Value display Operate display At the left you will find the Mode display and the Value display The Mode display is used to show error codes for testing and service purpose and for remote...

Page 7: ...mum of maintenance and the degausser has a built in diagnostics system to ensure that the required magnetic field strength is always produced If the diagnostics procedures detect a problem it will sho...

Page 8: ...upport Telephone 952 937 2121 E mail support krollontrack com Web www ontrackeraser com support Open 8 00 a m 5 00 p m M F CST International Contact Information Canada Canada 155 Gordon Baker Road Sui...

Page 9: ...2 30 22 E mail info ontrackdatarecovery be Norway Ibas Norge Postboks 1250 Arkoveien 14 2206 Kongsvinger Norway Web www ibas no Software Sales Free Telephone 47 62 81 01 00 Fax 47 62 81 01 10 E mail e...

Page 10: ...itor 1 is to hot cooling Stop Cap 3 n a Capacitor 1 is above 36 degree C FanCrtl Inside strapp set fan starts at 36 degree C Cap 1 Cap 2 Temp Capacitor 2 is to hot cooling Stop Cap 4 n a Remote Operat...