background image

Garantie

Bei nicht bestimmungsgemäßer
Verwendung, Aufstellung, Wartung,
wie in der Betriebsanleitung
vorgegeben oder eigenmächtigen
Änderungen an der werkseitig
gelieferten Geräteausführung erlischt
jeglicher Gewährleistungsanspruch.
Im Übrigen gelten unsere „Verkaufs-
und Lieferbedingungen“.
Technische Änderungen im Sinne der
Produktverbesserung vorbehalten.

Guarantee

Any use, installation, maintenance
that is not effected according to the
rules as asserted in the technical
manual, or unauthorized modifications
on the original version as delivered
from manufacturer leads to expiration
of any right to warranty.
Furtheron our „Conditions of Sales
and Delivery“ are valid.
Technical modification for product
improvement are subject to change
without notice.

Garantie

Toute utilisation, installation et
maintenance qui ne soit pas effectué
aux directives fixés dans le manuel
technique, ainsi que toute
modification

à

l´appareil livré du

fabricant dans sa version originale,
entraîne l´expiration du droit de
garantie.
En plus, nos „Conditions de vente et
de livraison“ sont en vigueur.
Sous réserve de modification
technique dans le sens d´amélioration
du produit.

Technische Änderungen im Sinne der Produktverbesserung vorbehalten!
Technical changes in the sense of product improvement reserved!
Toute modification réservée dans le but de l’amélioration du produit!

Kroll GmbH * Wärme- und Lüftungstechnik
Pfarrgartenstra

β

e 46 * Postfach 67

D-71737 Kirchberg/Murr

T49(0)7144/830

-0

  T49(0)7144/830-100

Kroll (UK) * Ltd.

Azura Close, Unit 49

Woolsbridge Industrial Estate - Dorest

 - Wimborne BH

216 SZ Three Legged Cross

Telefon

+44(0)120 28 222 21 ·  T44(0)120 28 222 22

Kroll France SA
651, avenue de la Plage, F-694 00 Villefranche-en-Beaujolais
Tél.

+33(0)474029540 ·  Fax +33(0) 474029541

Edit

14/11/2005

Summary of Contents for T40 Dual

Page 1: ...T 40 TE 40 T 40 TE 40 Artikel Nr 000111 01 Artikel Nr 000114 01 Luftentfeuchter Betriebs anleitung Dehumidifier Operating Instructions D shumidificateur Notice d utilisation Stand November 2005...

Page 2: ...eration syst m Preparation Setting into operation Indications Scope of application Malfunction and remedy Cleaning Technical data Circuit diagram T40 TE40 Spare parts Guarantee Page 2 2 3 4 4 5 5 6 7...

Page 3: ...the driver Your dealer must be notified of any technical damage before the appleance is assembled and set into operation The heater is only be started up after competent repair Attention Le d shumidi...

Page 4: ...T 40 TE 40 T 40 TE 40 3...

Page 5: ...Moist air in the room is drawn into the appliance and flows through the evaporator where it is cooled Wa ter vapour in the air condenses on the evaporator cooling surfaces and falls as water droplets...

Page 6: ...mmation de l nergie n est que de 30 de celle qu exige la d shumidification par chauffage Sch ma Circuit de refroidissement Verdampfer W rmeentzug der durchstr menden Raumluft Sammelbecken Verdichter V...

Page 7: ...pool or similar it must be fitted with a circuit breaker START Setting into operation Connect mains plug to a socket with 16 Amp fuse and earthing contact Adjust appliance to desired room humidity le...

Page 8: ...under 0 C b Blinks when temperature rises over again 0 C c Flashing will be stopped by mo mentary switching the unit off The device is equipped with an indication for eventual malfunction of the sensi...

Page 9: ...le swimming pools To dry damages due to humidity flood damage inundation The recommended humidity for living rooms is about 50 at 20 22 C Important Temperature humidity degree and operating conditions...

Page 10: ...n b Hygrostat Einstellung berpr fen c Kundendienst anfordern Der Entfeuchter l uft jedoch erfolgt keine Kondensierung am Verdamp fer a Arbeitsbereich Temperatur wurde unter oder berschritten b Arbeits...

Page 11: ...n nections b Check hygrostat setting c Contact after sales service Appliance runs but no condensation forms on evaporator a Operating temperature range not reached or exceeded b Operating air humidity...

Page 12: ...at c Demander le service apr s vente Le d shumidificateur fonctionne mais il n y a pas de condensation au vaporisateur a La plage de fonctionnement temp rature a t d pass e b Le degr hygrom trique min...

Page 13: ...eau avec d tergent laisser s cher puis le remonter dans l appareil Technische Daten Technical data Caract ristiques techniques Arbeitsbereich Operating humidity Plage d utilisation Feuchtigkeit range...

Page 14: ...mperature 8 Schwimmer Sensor 8 Sensor of floater position 8 Palpeur de position du flotteur 9 CINCH Stecker f r Hygrostat 9 CINCH connector for hygrostat 9 CINCH connecteur pour l hygrostat 10 Leuchtd...

Page 15: ...ante 20 022538 Steckdose Hygrostat socket for hygrostat hygrostat prise 21 035366 Betriebstundenz hler working hours meter compteur d heures de marche 22 004723 Hauptschalter main switch interrupteur...

Page 16: ...den oben angef hrten EG Richtlinien in alleiniger Verantwortung von is developped constructed and made according to the above mentioned EEC directives in responsibility of est d velopp construit et p...

Page 17: ...T 40 TE 40 T 40 TE 40 17...

Page 18: ......

Page 19: ......

Page 20: ...t maintenance qui ne soit pas effectu aux directives fix s dans le manuel technique ainsi que toute modification l appareil livr du fabricant dans sa version originale entra ne l expiration du droit d...

Reviews: