NDR1 – NDR6 connectors
The six NDR output F-connectors outputs the NDR signals
Over each connector are three red LED that indicates the activity of each input. Each
input can have 3 activities.
The ACTIVE LED is indicates that an active NDR signal is present.
The LCD LED is active if the input is being displayed on the LCD display.
The MP LED is active if the NDR output is copied to the MEASSURE POINT OUT connector
MEASURE OUTPUT
Each of the NDF1 to NDF3 and NDR1 to NDR6 signal can be measured using the MP
output. The output to the MP connector is selected using the joystick and will be
indicated on the MP LED.
ALL RF Connectors
All F-connectors connectors are mechanically
fi
xed in the chassis front by a double D-cut
hole. The connectors can withstand torques > 4,5 Nm (40 lb*inch)
All F-connectors are DC blocked up to 100V
All F-connectors are high quality CABLECON type.
Management Network Connector
The GbE is used for remote management and WEB access.
The RJ45 Network connector is supporting 10/100/1000 Mbit/s link speed, and half or full
duplex. MDIX is supported for both straight and crossed twisted-pair cables
LED indicators
The top left LED (green??) indicates that LINK is stablished The top right LED (orange??)
when
fl
ashing indicates that data is transmitted or received.
SFP+ connectors
P1 – P4 SFP+ connectors are used for NDR and NDF streaming. The data rate is
fi
xed
10GbE.
www.kronback.com | info@kronback.com
NDX Manual - Hardware description
8 of 24