background image

NDR1 – NDR6 connectors

The six NDR output F-connectors outputs the NDR signals 

Over each connector are three red LED that indicates the activity of each input. Each
input can have 3 activities. 

The ACTIVE LED is indicates that an active NDR signal is present.

The LCD LED is active if the input is being displayed on the LCD display.

The MP LED is active if the NDR output is copied to the MEASSURE POINT OUT connector

MEASURE OUTPUT

Each of the NDF1 to NDF3 and NDR1 to NDR6 signal can be measured using the MP
output. The output to the MP connector is selected using the joystick and will be
indicated on the MP LED.

ALL RF Connectors

All F-connectors connectors are mechanically 

xed in the chassis front by a double D-cut

hole. The connectors can withstand torques > 4,5 Nm (40 lb*inch) 

All F-connectors are DC blocked up to 100V

All F-connectors are high quality CABLECON type.

Management Network Connector

The GbE is used for remote management and WEB access.

The RJ45 Network connector is supporting 10/100/1000 Mbit/s link speed, and half or full
duplex. MDIX is supported for both straight and crossed twisted-pair cables

LED indicators

The top left LED (green??) indicates that LINK is stablished The top right LED (orange??)
when 

ashing indicates that data is transmitted or received. 

SFP+ connectors

P1 – P4 SFP+ connectors are used for NDR and NDF streaming. The data rate is 

xed

10GbE.

www.kronback.com | info@kronback.com

NDX Manual - Hardware description

8 of 24

Summary of Contents for NDR

Page 1: ...NDX Manual User Manual Kronback Tracers Copenhagen Denmark 45 46 907 909 info kronback com www kronback com Document date 2019 09 04 ...

Page 2: ...DR1 NDR6 connectors MEASURE OUTPUT ALL RF Connectors Management Network Connector LED indicators SFP connectors JOYSTICK GROUND TERMINAL DUAL PSU LCD LCD main screen LCD Network Configuration setup LCD spectrum HARDWARE SPECIFICATIONS Physical Specifications NDF Inputs NDR Output Network Interface NDR NDF LEDs Electrical AC powersupply www kronback com info kronback com NDX Manual Introduction 2 of ...

Page 3: ...e eth0 SFP1 interface eth1 SFP2 interface eth2 SFP3 interface eth3 SFP4 interface eth4 DNS IEEE 1588 MONITOR REMOTE PHY1 NDF1 to SFP1 SFP1 to NDR1 SFP1 to NDR2 REMOTE PHY2 REMOTE PHY3 SOFTWARE UPDATE www kronback com info kronback com NDX Manual Introduction 3 of 24 ...

Page 4: ...t SFP Small_form factor pluggable transceiver IPv6 Internet Protocol version 6 IPv4 Internet Protocol version 6 IEEE Institute of Electrical and Electronics Engineer AC Alternate Current L2TP Layer 2 tunneling protocol LCD Licuid crystal display LED Light emmiting diode NDX Kronback Tracers OOB gateway www kronback com info kronback com NDX Manual Acronyms 4 of 24 ...

Page 5: ...X can be ordered in 115V 230V AC as well as 48V configuration NDF The NDX provides 3 parallel NDF channels Each channel can be individually configured to a center frequency between xx and 862 MHz Mode 0 to 7 are supported The input level of each input can be adjusted in a 30dB range to meet the required 1 41 RMS output level S6 3 format The NDF input signal can be monitored by the 20dB test point ou...

Page 6: ...r sessions in a digitally combining After the combining of 16 sessions the combined NDR carrier again combined with 2 other NDR carriers a total of 3 carriers are present on the NDR output connector A common 30 dB attenuator can be used to adjust the coarse level of the 3 output carriers The NDF input signal can be monitored by the 20dB test point output on the front of the NDX on the LCD screen o...

Page 7: ...eaming using the three NDF F connectors Over each connector are three red LED that indicates the activity of each input Each input can have 3 activities The ACTIVE LED is indicate that the input is active streaming NDF data The LCD LED is active if the input is being displayed on the LCD display The MP LED is active if the NDF input is copied to the MEASSURE POINT OUT connector www kronback com in...

Page 8: ...nectors All F connectors connectors are mechanically fixed in the chassis front by a double D cut hole The connectors can withstand torques 4 5 Nm 40 lb inch All F connectors are DC blocked up to 100V All F connectors are high quality CABLECON type Management Network Connector The GbE is used for remote management and WEB access The RJ45 Network connector is supporting 10 100 1000 Mbit s link speed...

Page 9: ... the screen a fold out menu will appear when selecting the DOWN key GROUND TERMINAL The ground termination screw is connected to the chassis ground of the X16 NOTE Proper grounding is critical to avoid hazard and to avoid damaging equipment due to voltage differences DUAL PSU The Dual PSU s are hot swap replaceable LCD Selecting a sub menu is done by pushing the joystick or selecting the RIGHT key ...

Page 10: ...INTERNAL TEMPERATURE The LCD main screen summarizes the status and alerts of the NDX The serial number is displayed and the internal FPGA temperature is shown The 5 IP addresses are shown in the bottom in sequence www kronback com info kronback com NDX Manual Hardware description 10 of 24 ...

Page 11: ...ecomes black To deactivate DCHP pres right again the dot becomes white The management interface eth0 IP address is configured from the Network Configuration menu Scroll down to each line and then step right through each number to modify the IP address Netmask and Gateway settings The last step will commit the changes and to cancel changes step out to the left intead www kronback com info kronback co...

Page 12: ...nal can be displayed in the spectrum graph of the LCD display The signal to be monitored is selected using the joystick and will be indicated on LCD screen and also the associated MP LED Measure point LED wil light In the above example the NDF1 spectrum is displayed www kronback com info kronback com NDX Manual Hardware description 12 of 24 ...

Page 13: ...Hz ADC Full scale Dynamic range 1 CW 80 110 dBuV 1 NDF channel per F connector Mode 0 to 7 Input power attenuation 30dB Impedance 75 Ohm Return loss 16dB RF level accuracy 0 5dB Isolation to all input outputs 60 dB NDR Output R4 2 3 100 The NDX supports 6 NDR ports each of which supports the following physical and transmission characteristics Connector BNC type AC coupled 100V DC isolation Frequen...

Page 14: ... Digital combining of up to 16 NDR streams of same mode IPv6 NDF 3 NDF streams NDF Mode 0 7 IPv6 LEDs The NDX supports the following LEDs 3 LEDs indicating NDF activity 6 LEDs indicating NDR activity 9 LEDs indicating activity on LCD screen 9 LEDs indicating output to 20dB Measure Point 2 LEDs indicating PSU status 8 LEDs indicating Link and activity on SFP modules 2 LEDs indicating Link and activ...

Page 15: ...independant dual hot swappable PSU plug in units 48V DC powersupply 48V DC terminal Reverse polarity protection Power consumption 50 Watts 2 independant dual hot swappable PSU plug in units www kronback com info kronback com NDX Manual HARDWARE SPECIFICATIONS 15 of 24 ...

Page 16: ...is page is applied immediately without needing reboot Management interface eth0 DHCP Activate DHCP If checked the interface will use DHCP to obtain its IP configuration Only IPv4 is supported with DHCP Type On Off IPv4 Addr Netmask Enter IPv4 address mask for the interface Ignored if DHCP is enabled Type String IPv4 Gateway Gateway for the interface Enter an IPv4 address to use as gateway or leave b...

Page 17: ... IPv6 Gateway Gateway for the interface Enter an IPv6 address to use as gateway or leave blank for no gateway Ignored if DHCP is enabled Type String Loopback Only for testing Check to enable internal and external loopback Type On Off SFP2 interface eth2 Enable Check to enable the SFP2 module Type On Off IPv4 Addr Netmask Enter IPv4 address mask for the interface Ignored if DHCP is enabled Type Strin...

Page 18: ...ter IPv4 address mask for the interface Ignored if DHCP is enabled Type String IPv4 Gateway Gateway for the interface Enter an IPv4 address to use as gateway or leave blank for no gateway Ignored if DHCP is enabled Type String IPv6 Addr Netmask Enter IPv6 address mask for the interface Ignored if DHCP is enabled Type String IPv6 Gateway Gateway for the interface Enter an IPv6 address to use as gat...

Page 19: ...teway Gateway for the interface Enter an IPv6 address to use as gateway or leave blank for no gateway Ignored if DHCP is enabled Type String Loopback Only for testing Check to enable internal and external loopback Type On Off DNS DNS server 1 DNS server 1 Type String DNS server 2 DNS server 2 Type String IEEE 1588 The device supports accurate synchronization of the reference clock using the PTPv2 p...

Page 20: ...sec Number of SYNC messages per second to request in unicast negotiation Supported values 1 2 4 8 16 32 Default 8 Type Integer Unit per sec Multiple messages filter Method for processing multiple SYNC messages received since last servo update Default minimum For example with minimum the servo update calculation will use the SYNC message with the minimum time difference of the available SYNC messages...

Page 21: ...nit ns Reject max count The maximum number of consecutive SYNC messages allowed to be rejected before a new time offset is adopted Enter 0 here to disable reject system Default 8 Type Integer MONITOR On this page the MP output monitor function can be configured REMOTE PHY1 On this page NDF and NDR can be configured for the following streaming channels NDF1 to SFP1 SFP1 to NDR1 SFP1 to NDR2 NDF1 to SF...

Page 22: ...abling test mode will make NDX always start streaming regardless of the network situation likely to an undefined MAC address Only for testing Type On Off Gain Digital scaling of signal Enter a smaller number here to attenuate the signal digitally Type Integer range 0 65535 Att Analog attenuation of signal Entering larger numbers here will enable larger analog attenuation of the signal Type Decimal r...

Page 23: ... number here to attenuate the signal digitally Type Integer range 0 65535 Att Analog attenuation of signal Entering larger numbers here will enable larger analog attenuation of the signal Type Decimal range 0 31 SFP1 to NDR2 Enable Type On Off Mode Select bandwith mode Mode 7 is 25 6 MHz 6 is 5 12 MHz 5 is 2 56 MHz 4 is 1 28 MHz Options 7 6 5 4 3 2 1 0 Frequency Specify center frequency Type Intege...

Page 24: ...range 0 31 REMOTE PHY2 This pages is similar to REMOTE PHY1 but configures the streaming channels NDF2 to SFP2 SFP2 to NDR3 SFP2 to NDR4 REMOTE PHY3 This pages is similar to REMOTE PHY1 but configures the streaming channels NDF3 to SFP3 SFP3 to NDR5 SFP3 to NDR6 SOFTWARE UPDATE This page shows information about the NDX software version and provides features for updating the software www kronback com...

Reviews: